Service Manual
SummaSign
KNIFE CALIBRATION ( tangential)
It is recommended to recalibrate the knife each time it is changed. See section
1.5.1. for the calibration procedure.
COIL CALIBRATION
The coil has to be recalibrated when:
the head is changed
the PCB is changed
when the cut quality is dubious
Calibration:
Power the machine up when there is no media loaded and while the knife is turned
up.
Go to internal system tests - coil set-up. Press the
key.
The following message is displayed on the LCD :
40 g PRESSURE
19
In the upper line of the LCD the desired pressure is
displayed and the bottom line shows the value that has
to be sent to the head to reach the pressure displayed.
Press the
key.
The following message is displayed on the LCD :
600 g PRESSURE
110
If you have a tension gauge of ± 600g you can check if the pressure is 600 gr. You
can adjust the 600gr pressure with the pot-meter located right besides the
connector for the LCD en keyboard on the main PCB. (the max. pressure with a
drag machine is 400grs).
If you don’t have a tension gauge, leave it at 110 .
Press the
key.
The following message is displayed on the LCD :
40 g PRESSURE
19
If you have a tension gauge of ± 100g you can check if the pressure is 40 gr. If a
value lower than 40 gr. is shown on the tension gauge press the
key to
Calibration
4-7
Summary of Contents for SummaSign D1010
Page 1: ...Service Manual SummaSign Series Summa NV Rochesterlaan 6 8470 Gistel Belgium...
Page 80: ...SummaSign Service Manual 106 107 2 36 Replacements Guidelines Blank page...
Page 85: ...Service Manual SummaSignT se 3 2 OPERATING VOLTAGE CONVERSION Maintenance and Cleaning 3 5...
Page 87: ...Service Manual SummaSignT se Maintenance and Cleaning 3 7 blank page...
Page 92: ...Service Manual SummaSign Calibration 4 5...
Page 93: ...SummaSign Service Manual HEAD CALIBRATION 4 6 Calibration...
Page 131: ...Service Manual SummaSign Spare Parts List 7 13...
Page 134: ...Summasign Service Manual 7 16 Spare Parts List...