SummaSign Pro SL D-series Cutters
User’s Manual
Operation 2-28
2.6.8
RAM TEST
This test completely checks the RAM bit for bit.
The cutter will not respond when this test is in progress. After this test is complete,
power the cutter off and then back on.
2.6.9
INSTALL MENU
The INSTALL MENU procedure restores the factory-defined menu settings in all
four USER CONFIG menus. This procedure can be performed without a tool or
media.
2.6.10
COIL SETUP
This procedure is used to calibrate the knife and pen pressures, and to set the
knife and pen “landings”.
After calibration, the values are saved in the system’s non-volatile RAM.
A tension gauge of ± 100 gr and ± 500 gr is required to execute this test.
The desired pressure appears in the upper line of the display. The bottom line of
the display indicates the value that has to be sent to the head in order to reach
the desired pressure (this value is between 0 and 127).
2.6.11
LCD CONTRAST
The LCD CONTRAST submenu is used to adjust the contrast (or intensity) of the
liquid crystal display on the control panel.
Press the
or
jogging key to increase or decrease the contrast, then press
to apply the new setting.