SummaSign Pro T-series Cutters
User’ s Manual
Operation
2-21
•
Concentricity misalignment
. The knife tip is slightly rotated in relation to its
theoretical 0
°
angle. This error can be corrected by means of the ADJUST
ORIGIN test routine.
•
Horizontal misalignment
. The knife tip deviates from its theoretical
longitudinal centre. This error can be corrected by means of the ADJUST
LONG. test routine.
•
Vertical misalignment
. The knife tip deviates from its theoretical lateral
centre. This error can be corrected by means of the ADJUST LAT. test
routine.
LONGITUDINAL deviation
LATERAL deviation
Theoretical centre
of the knife
Theoretical 0º
angle of the knife
ORIGIN deviation
FIGURE 2-5:
POSSIBLE KNIFE CALIBRATION GROUNDS
The calibration settings entered during the knife calibration routine are
automatically stored in the cutter’ s memory and will be maintained after
power down.
NOTE
Prior to knife calibration, load vinyl and install a knife to avoid
damage to the cutting strip.