Maintenance and Cleaning
3-4
3.2. OPERATING VOLTAGE CONVERSION
The power entry module cover shows four possible AC voltage settings (100 V,
120 V, 230 V and 240 V). The pin in one of the holes indicates the cutter's active
voltage setting. If this setting does not match the voltage supplied to your site,
you must change the voltage
BEFORE
powering on the cutter.
When changing the voltage setting, you will also have to change the fuses as
appropriate to the voltage.
To change the fuse(s), remove the fuse(s) from the fuse box behind the cover
plate of the power entry module.
For 100 or 120 V AC operation use only a 1.25 A Slo-Blo fuses.
For 230 or 240 V AC operation use only a 0.6A Slo-Blo fuses.
NOTE
Always make sure that you are using the correct fuses for your
voltage selection.
FIGURE 3-3
POWER ENTRY MODULE