4
Summer Fun
(1)
Min. 2
Meter
circulation
pump
Filter
(2)
A free area of minimum 0,3 meter around the heat pump has to be kept clear from
any object
(1).
Do not obstruct the fan, leave at least 1.5m free unobstructed space in front of the fan.
All feeding of water treatment to the pool water has to be done downstream of the heat pump(2)
Put the heat pump on a flat, solid base.
It is normal for condensation water to come out of the heat pump when it is operating. This is not a fault or
leak!
It is normal for condensation to come out of the heat pump. This is not a leak or fault with the unit. If the
humidity is very high, the condensation could be a number of liters a day.
4. Preparing the heat pump for use
4.1. Typical configuration & distance from the pool
The heat pump should be located at least 2m away from the swimming pool. In normal operation, the air taken
by the heat pump is cooled down and water may condens on the fins of the evaporator and run out of the
bottom of the unit.
4.2. Hose connection.