4
5
VENTILATION PERFORMANCE
EXT. STATIC
NET SUPPLY
GROSS AIR FLOW
PRESSURE
AIR FLOW
SUPPLY
EXHUAST
Pa
in. w.c.
L/S
CFM
L/S
CFM
L/S
CFM
25
0.1
98
209
100
213
92
196
50
0.2
92
196
94
199
87
186
75
0.3
86
182
87
186
82
174
100
0.4
79
169
81
172
76
162
125
0.5
68
145
70
148
70
148
150
0.6
58
124
59
126
60
127
SPECIFICATIONS HEAT RECOVERY VENTILATORS PERFORMANCE RATINGS
ENERGY PERFORMANCE
LATENT
RECOVERY/
MOISTURE
TRANSFER
SUPPLY
TEMPERATURE
NET
AIR FLOW
POWER
CONSUMED
WATTS
SENSIBLE
RECOVERY
EFFICIENCY
APPARENT
SENSIBLE
EFFECTIVENESS
C°
F°
L/S
CFM
HEATING
0
32
30
64
83
71
82
0.01
0
32
46
97
104
67
77
0.00
0
32
61
129
117
66
73
0.00
-25
-13
31
66
95
58
79
0.03
TOTAL RECOVERY EFFICIENCY
COOLING
35
95
31
65
83
18
SUMMERAIRE MFG.,
PETERBOROUGH, ONTARIO K9J 6X6
MODEL: SHRV130RD
Options Installed:
Defrost Internal Dehumidistat
Electrical:
120 V - 1.27 Amp
Exhaust Air Transfer Ratio:
.02
Low Temp. Ventilation Reduction During -25°C Test: 20%
Maximum Unbalanced Airflow During -25°C Test: 7 L/s
FRESH AIR
FROM
OUTSIDE
STALE AIR
TO
OUTSIDE
FRESH AIR
TO
HOUSE
STALE AIR
FROM
HOUSE
36
17 3/4
20 3/4
200
175
150
125
100
75
50
25
0
20
40
60
80
100
120
Supply
Exhaust
Gross Airflow - L/s (CFM = L/s
÷
.47)
E
xt
.D
if
fe
re
nt
ia
lP
re
ss
ur
e
-
P
as
ca
ls
(I
N
W
.C
.=
PA
÷
25
0)