OPERATING INSTRUCTIONS
CAUTION:
NEVER BURN GARBAGE, REFUSE OR PAPER IN THE HEATING UNIT.
NEVER LEAVE COMBUSTIBLE OR OTHER MATERIALS AROUND OR NEAR THE FURNACE.
IDENTIFY THE LOCATION OF YOUR BURNER / FURNACE POWER SWITCH
OIL BURNER OPERATING INSTRUCTIONS
• Use No 2 furnace oil
ONLY
• Do not use gasoline, crankcase oil, or any oil containing gasoline.
• Do not attempt to start the burner if excess oil has accumulated, when the furnace is full of vapor,
or if the combustion chamber is hot.
• Press the burner relay reset button ONLY ONCE; if the burner fails to start, call an
Oil Burner Technician.
• If the oil burner is to be shut off for any period of time, shut the oil valve OFF at the oil tank.
• Do not adjust or tamper with the furnace or any of the controls
• Do not burn garbage or paper in this unit.
• Never leave paper, rags, or other combustibles around the furnace.
• Only qualified, or where required by law, a licensed technician shall set – up this unit and
adjust controls.
• DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE.
TO TURN THE BURNER OFF
• Turn the main oil burner switch to “ OFF “
• Set the thermostat as far below room temperature as possible.
IF BURNER IS TO BE SHUT OFF FOR AN EXTENDED PERIOD.
• Turn main oil burner switch to “OFF”.
• Close all oil supply valves.
• The heating system should be checked and cleaned if necessary.
RESTARTING BURNER AFTER EXTENDED SHUT DOWN.
The complete oil burner should be checked and serviced by a qualified technician.
• Check oil pump strainer
• Replace oil filter cartridge
• Check electrodes
• Oil burner motor ( see lubrication section )
• Restart burner by following instructions in; “ STARTING THE OIL BURNER “ section.
• If your furnace has been shut off for an extended period – contact your qualified service technician
for start - up