MPE-200 Guide to Operations
Page 17
MASTER SETUP (ctd)
Fader
Enable
The last item of the Master Setup screen enables the Fader screen.
If set to No Fade, the Fader Screen is bypassed, and the Fader
attenuator is set fully on (0 dB). Push the knob until No Fade/Fader
is blinking, and turn the knob to enable or disable the Fader page.
5.5
OUTPUT FADER screen (dark green).
Fader screen
Channel A has 39 dB of attenuation
Channel B has 72 dB of attentuation
Both channels are enabled for Fade
The output fader approximates a standard fader curve, with –20 dB
occuring at mid-scale. The fader is always in fine mode, with 64
steps covering the full range.
[
*
]
The precision attenuator is after the meter and peak
sensing in the signal path, so it should always be set to
“0” unless doing a fade.
Pressing the knob selects either or both channels to fade. Each
channel can be controlled separately, even if the Master channel
mode is Stereo, and any offset is retained when switching back to
stereo fade. Settings are not stored and will be discarded when the
fader is disabled, or when a new preset loaded.
Fade
-39
-72