(Controls, continued)
indicator is a warning light, notifying the operator that the
container is beginning to near its “full” point. When the platen
moves forward and reaches a pre-set amount of resistance, the
light in the “START” button will blink slowly. As the container
fills and that preset resistance is reached earlier in the platen’s
forward stroke, the light will blink at a medium speed. When the
compactor is nearing the end of its ability to compact more
material into the container, the light will blink fast. Finally,
when the container is full, the ram will stop in its forward-most
position and this light will remain lit.
NOTE: If your compactor
is equipped with a OnePlus brand “Waste Edge” monitoring
system, management will know when it is time to empty the
container, and you can ignore the Packing Progress Indicator
Light.
Emergency Ram Control
Emergency Ram Control
Emergency Ram Control
Emergency Ram Control. Your compactor is provided with a
three-position toggle switch for the purpose of moving the
compactor platen forward or back manually. To move the platen
forward, use the “FORWARD” or “EXTEND” function of the
switch; to move the platen backward, use the “REVERSE” or
“RETRACT” function. The Emergency Ram Control is also used
to adjust standard or optional settings; see the paragraphs below
for "Setting number of strokes" and "Setting number of door
closes before cycle (optional)."