10
1. 3-Wire Power Cord Installation
IMPORTANT:
Use the 3-wire cable from power supply where local codes permit connecting the
frame-ground conductor to the neutral (white) junction box wire.
1. Disconnect the power.
2. Remove the junction box cover, if present.
3. Connect the flexible cable conduit (3) from the
cooktop to the junction box (4) using a UL listed
or CSA approved conduit connector (7).
4. Tighten the screws on conduit connector, if
present.
5. Connect the two black wires (1) together using
the UL listed wire nut (5).
6. Connect the two red wires (2) together using the
UL listed wire nut.
7. Connect the green wire (6) to the white (neutral)
wire (6) in the junction box using the UL listed
wire nut.
8. Replace the junction box cover.
9. Reconnect power.
2. 4-Wire Power Cord Installation
IMPORTANT:
Use the 4-wire cable from power supply where local codes do not permit connecting
the frame-ground conductor to the neutral (white) junction box wire.
1. Disconnect the power.
2. Remove the junction box cover if present.
3. Connect the flexible cable conduit (3) from the
cooktop to the junction box (4) using a UL listed
or CSA approved conduit connector (7).
4. Tighten the screws on conduit connector, if
present.
5. Connect the two black wires (1) together using
the UL listed wire nut (5).
6. Connect the two red wires (2) together using the
UL listed wire nut.
7. Connect the green wire (6) from the cooktop
cable to the green wire (6) (in the junction box)
using the UL listed wire nut.
8. Put a UL listed wire nut on the end of the white
wire (8).
NOTE:
Do not connect the bare ground wire to the neutral (white) wire in the junction box.
9. Replace the junction box cover.
10. Reconnect power.