9
NOTE:
Use the 3-wire cable from the power supply, where local codes permit, connecting the frame-
ground conductor to the neutral (blue) junction box wire.
1.
Disconnect the power supply.
2.
Remove the junction box cover if present
3.
Connect the flexible cable conduit (3) from the cooktop to the junction box (4) using a UL
listed or CSA approved conduit connector (7).
4.
Tighten screws on conduit connector if present.
5.
Connect the two brown wires (1) together using the UL listed wire nut (5).
6.
Connect the two blue wires (2) together using the UL listed wire nut.
7.
Connect the two green wires (6) together using the UL listed wire nut (5).
8.
Install the junction box cover.
9.
Reconnect the power.