IMPORTANT SAFETY INSTRUCTIONS 

WARNING

   

To reduce the risk of fire, electrical shock or injury when using your appliance, 

follow these basic precautions:

 

 

Read all instructions before using the appliance. 

  Plug into a grounded 3-prong outlet. Do not remove grounding prong, do not use an adapter, and do not use 

an extension cord. 

  It is recommended that a separate circuit, serving only your appliance, be provided. Use receptacles that 

cannot be turned off by a switch or pull chain. 

  Never clean appliance parts with flammable fluids. These fumes can create a fire hazard or explosion. 

  Before proceeding with cleaning and maintenance operations, make sure the power line of the unit is 

disconnected. 

  Do not connect or disconnect the electric plug when your hands are wet. 

  Unplug the appliance or disconnect the power before cleaning or servicing. Failure to do so can result in 

electrical shock or death. 

  Do not attempt to repair or replace any part of your appliance unless it is specifically recommended in this 

manual. All other servicing should be referred to a qualified technician. 

 

Do not store or use gasoline or any other flammable vapors and liquids  in the vicinity of this or any other 
appliance. The fumes can create a fire hazard or explosion. 

  Use two or more people to move/install 

the refrigerator

. Failure to do so can result in back or other injury. 

  To ensure proper ventilation for your appliance, the front of the unit must be completely unobstructed. 

Choose a well-ventilated area with temperatures above 61

°

F (16

°

C) and below 95

°

F (35

°

C). This unit must 

be installed in an area protected from the elements, such as wind, rain, water spray or drips. 

  The appliance should not be located next to ovens, grills or other sources of high heat. 

  The appliance must be installed with all electrical connections in accordance with state and local codes. A 

standard electrical supply (115V AC only, 60 Hz), properly grounded in accordance with the National 
Electrical Code and local codes and ordinances, is required. 

  Do not kink or pinch the power supply cord of the appliance. 

  The fuse (or circuit breaker) size should be 15 amps. 

  It is important for the appliance to be leveled in order to work properly. You may need to make several 

adjustments to level it. 

  Although the unit has been tested at the factory, due to transit and storage, you should clean the appliance 

before use. 

  Do not use solvent-based cleaning agents or abrasives on the interior. These cleaners may damage or 

discolor the interior. 

  Do not use this apparatus for other than residential purposes. 

  This appliance is CFC- and HFC-free and contains small quantities of Isobutane (R600a) which is 

environmentally friendly, but flammable. It does not damage the ozone layer, nor does it increase the 
greenhouse effect. Care must be taken during transportation and setting up of the appliance that no parts of 
the cooling system are damaged. Leaking coolant can ignite and may damage the eyes. 

  In the event of any damage: 

-    Avoid open flames and anything that creates a spark, 
-    Disconnect from the electrical power line, 
-    Air the room in which the appliance is located for several minutes, and 
-    Contact the Service Department for advice. 

  The more coolant there is in an appliance, the larger the room it should be installed in. In the event of a 

leakage, if the appliance is in a small room, there is the danger of combustible gases building up. For every 
ounce of coolant, at least 325 cubic feet of room space is required. The amount of coolant in the appliance 
is stated on the data plate on the back of the appliance. It is hazardous for anyone other than an authorized 
Service Person to carry out servicing or repairs to this appliance. 

  Take serious care when handling, moving, and using the appliance to avoid either damaging the refrigerant 

tubing or increasing the risk of a leak. 

  Replacing component parts and servicing shall be done by factory authorized service personnel so as to 

minimize the risk of possible ignition due to incorrect parts or improper service. 

 

 

Summary of Contents for FF1843BKS

Page 1: ...EFRIGERATOR Model FF1843B Owner s Manual BEFORE USE PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS Felix Storch Inc Summit Appliance Division An ISO 9001 2008 registered company 770 Garrison Avenue Bronx NY 10474 www summitappliance com ...

Page 2: ...y grounded in accordance with the National Electrical Code and local codes and ordinances is required Do not kink or pinch the power supply cord of the appliance The fuse or circuit breaker size should be 15 amps It is important for the appliance to be leveled in order to work properly You may need to make several adjustments to level it Although the unit has been tested at the factory due to tran...

Page 3: ...ct sunlight and sources of heat stove heater radiator etc Direct sunlight may affect the acrylic coating and heat sources may increase electrical consumption Extremely cold ambient temperatures may also cause the unit not to perform properly Avoid locating the unit in moist areas Plug the appliance into an exclusive properly installed and grounded wall outlet Do not under any circumstances cut or ...

Page 4: ... your unit in extremely cold or hot conditions may cause the interior temperature to fluctuate ON OFF Power To turn the appliance on or off press the ON OFF button Setting the Temperature Control Once the power cord has been connected to a properly grounded outlet press the button Set the desired cooling temperature by pressing the corresponding button or Each depression of the buttons will raise ...

Page 5: ...ace of the door This occurs when water vapor from the air contacts the cold surface of the door and the vapor condenses on the door causing a fogging effect In extreme situations water can even drip off the door indicating excessive humidity in the environment If the unit is unplugged or turned off or if there has been a power failure you must wait 3 to 5 minutes before restarting the unit If you ...

Page 6: ... compressor and evaporates automatically Power Failure Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If your power is going to be off for a longer period of time you need to take the proper steps to protect your contents Vacation Time Leave the appliance operating during vacations ...

Page 7: ...ns on and off frequently The room temperature is hotter than normal A large amount of contents has been added to the unit The door is opened too often The door is not closed completely The temperature control is not set correctly The door gasket does not seal properly Vibrations Check to be sure that the refrigerator is level Refrigerator seems to make too much noise Some noise may come from the f...

Page 8: ...epair labor costs for units operated outside the United States 5 Repairs to parts or systems resulting from unauthorized modifications made to the appliance 6 The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOL...