OWNER’S MANUAL

Initial Startup  

Before starting the pool heater for the first time, it is important to verify that 
the breaker is in the ON position.  

Also make sure that the water circulates freely and that the pool pump is activited.  

Then,  you  will  need  to  set  the  water  temperature  you  desire.  The  fan  will  
immediately start. The compressor will start after a 3 to 4-minute delay.  

When the compressor is running, the 

HEATING/CHAUFFAGE

 indicator located 

on the right (see “Service Analyzer Control,” p. 13) should be lit. At initial startup, 
it is normal for the unit to run 24 hours a day.  

It is also normal to see water dripping from the holes at the base of the unit. 
This is just condensation.   

IMPORTANT

?

16

Summary of Contents for Pool Heat Pump

Page 1: ...Owner s Manual PRINTED IN CANADA 05 2009...

Page 2: ......

Page 3: ...instructions 8 Using an External Controller 10 Electrical Connections 11 Wiring Diagram 12 Service Analyzer Control 13 Operation 14 Caring for your Pool Heater 15 Initial Startup 16 Meaning of Display...

Page 4: ...aters such as gas or oil fired the SUMMIT pool heat pump has a lower heating capacity on a BTU hr basis Therefore it needs to operate for a longer time to accomplish the desired results Occasionally i...

Page 5: ...of your heater Please also record the purchase date of your device and your dealer s name address and telephone number Model Number_____________________________________________________ Serial Number__...

Page 6: ...task CAUTION The CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in material damage particul...

Page 7: ...arances needed for proper operation and heating CAUTION Proper pool chemistry is vital to the life of your heater Pay particular attention to the total alkalinity and TDS It is highly recommended that...

Page 8: ...least all around your heat pump The use of 90 degree bends and short radius elbows in the water piping should be kept to a minimum Mount the unit on a sturdy base preferably a concrete slab or a set...

Page 9: ...le hose but make sure the hose can withstand high pressure The installation of a bypass is not necessary unless the water flow exceeds 80 GPM Note Certain installations have valves which isolate the h...

Page 10: ...uipment All electric and metal components must then be bonded to each other and then to the copper rod CAUTION 1 A 1 3 lb check valve must be installed between the heater and any automatic chlorine di...

Page 11: ...Owner s manual Bonding and Plumbing diagram Fig 2 Fig 3 SUMMIT 9...

Page 12: ...ng an external switch follow these steps Turn on the heat pump Set POOL mode to OFF Set SPA mode to the desired temperature Access the setup menu Select mode E external on the P_S menu Run two J7 P_S...

Page 13: ...then slide the electric cable in the hole located on the left or the right side of the base and then insert it in the control box The electrical diagram is located on the lid of the control box as wel...

Page 14: ...er sensor Defrost sensor High pressure switch Closed OK Opened high pressure Low pressure switch Closed OK Opened low pressure Flow switch Closed flow Opened no flow Remote switch Pool opened Spa clos...

Page 15: ...e temperature in Fahrenheit degrees 13 Temperature and parameter display Celsius or Fahrenheit mode Access to parameters To raise the desired temperature or to change parameters To lower the desired t...

Page 16: ...ccess to either program press the SET key until you see P_S and by press ing one of the arrow keys you can switch to POL or SPA Once the heating mode has been programmed it will be displayed for five...

Page 17: ...Owner s manual Caring for your Pool Heater How to protect your pool heater 15...

Page 18: ...eed to set the water temperature you desire The fan will immediately start The compressor will start after a 3 to 4 minute delay When the compressor is running the HEATING CHAUFFAGE indicator located...

Page 19: ...wa ter flow Backwash filter and or heater The unit will show HP3 after 3 HP faults This will stop your heater for protection Po Water temperature probe connected to 1 and 2 on electronic board may be...

Page 20: ...is running but the compressor is not Pool pump is not running Filter is dirty restricting the water flow Turn the pool pump on Backwash and clean filter The heater is displaying flo and it will not s...

Page 21: ...ing mode a large quantity of warm and humid air passes over the evaporator and causes con densation It is normal to see condensation dripping under the heater To check if the water really is a leak yo...

Page 22: ...ections or call your dealer It may save you the cost of a service call If you still need help follow the instructions below Service can be obtained by calling one of these phone numbers CANADA 1 888 2...

Page 23: ...st you must turn the breaker off The unit must be drained of all its water You will need to disconnect the IN and OUT water connections Then the unit must be tilted or blown out with air until all wat...

Page 24: ...be null and void All warranty work must be performed by a Hayward Industries authorized service center All warranty work must be approved prior to service center performing the work Any alteration or...

Reviews: