background image

EV40 User’s Manual 

Refer to the Customer Support section in this manual for information on the Service 
Representative in your area.  

• Not for use in commercial garages where a COMMERCIAL GARAGE is defined as a 

facility (or portion thereof) used for repair of internal combustion vehicles in which the 
area is classified due to flammable vapours being present (such as from gasoline) 

• Do not place fingers inside of the coupler end of the 

SAE-J1772™ 

charge cable. 

• Do not allow children to operate this device. Adult supervision is mandatory when children 

are in proximity to a charge station that is in use. 

Instructions concernant des risques d' incendie ou de choc électrique

Lorsque vous utilisation de la EV40, précautions fondamentale sécurité électrique doivent être 
suivies:

 

• Utilisez cette station de charge pour charger les véhicules électriques équipés d'un 

SAE 

J1772™

  port de recharge seulement. Consultez le manuel du propriétaire du véhicule afin 

de déterminer si le véhicule est équipé d'un correcte port de recharge . 

• Assurez-vous que le 

SAE J1772™

 câble de recharge sur la station de recharge est 

positionné de telle sorte qu'il ne sera pas piétiné, accroché plus du, ou autrement 
endommagé ou de subir la stress. 

• Ce produit ne contient aucune pièce réparable par l'utilisateur. Consultez la section Support 

à la Clientèle dans ce manuel pour obtenir des informations de service. N’essayez pas de 
réparer ou d'entretenir la station de recharge vous-même. 

• Ne faites pas fonctionner votre station ou le câble de charge si elles sont physiquement 

ouverte,  fissuré, effiloché, ou autrement visiblement endommagé . Contactez votre 
représentant de service pour service immédiatement. Consultez la section Support à la 
Clientèle dans ce manuel pour obtenir des informations sur le représentant du service dans 
votre région. 

• Ne pas utiliser dans les garages commerciaux où un garage commercial est défini comme 

une installation (ou une partie) utilisé pour la réparation de véhicules à combustion interne 
dans lequel la zone peut être classée en raison de vapeurs inflammables étant présent 
(comme l'essence) 

• Ne posez pas vos doigts dans de l’intérieur de l’extrémité du 

SAE J1772™

 coupleur du 

câble de recharge. 

• Ne pas laisser les enfants utiliser cet appareil . Supervision d'un adulte est obligatoire 

lorsque des enfants sont à proximité d'une station de charge qui est en cours d'utilisation .

Page 2

Summary of Contents for ev40

Page 1: ...GRE ENI NG THE WORLD S HIG HWAYS User s Manual EV40...

Page 2: ...otice Changes or modifications to this product by other than an authorized service facility could void the product warranty If you have questions about the use of this product contact your customer se...

Page 3: ...N 3 FCC INFORMATION 4 OPERATION 4 EV40 FRONT PANEL 5 INSTALLATION 6 Service Connections 6 Mounting Procedures 10 Wiring Instructions 14 Grounding Instructions 15 MOVING STORAGE INSTRUCTIONS 15 MAINTEN...

Page 4: ...accidents AVERTISSEMENT Ce symbole signifie danger Vous tes dans une situation qui pourrait causer des blessures corporelles Avant de travailler sur un quipement lectrique tre conscient des dangers pr...

Page 5: ...recharge est positionn de telle sorte qu il ne sera pas pi tin accroch plus du ou autrement endommag ou de subir la stress Ce produit ne contient aucune pi ce r parable par l utilisateur Consultez la...

Page 6: ...du propri taire du v hicule pour d terminer si votre v hicule n cessite une ventilation quand le recharge en salle Note Vehicles which conform to the SAE J1772 standard for communication with the char...

Page 7: ...eut annuler la conformit FCC OPERATION The EV40 Electric Vehicle Charging station is a compact wall or pedestal mounted charging station that provides the Plug in Hybrid or Battery Electric Vehicle to...

Page 8: ...ications Disconnect and restart ON off off Blinking EV ground fault trip Check vehicle connection ON off Blinking Blinking Internal EVSE fault Call for service Page 5 POWER yellow indicates that power...

Page 9: ...is not required by the EV40 Charger Only Line 1 Line 2 and Ground are required as shown in Fig 3 Attention Il s agit d un appareil monophas Ne pas relier tous les 3 phases d un alimentation triphas e...

Page 10: ...connection is definitely known and the 3 wires from the main circuit breaker panel are connected and labeled correctly Figures 2 3 and 4 below show the most common service transformer secondary wiring...

Page 11: ...For example L1 L2 or L1 L3 or L2 L3 Leave the unused leg open Do not connect it to a Neutral bar or to Ground Be sure the center point is grounded to earth somewhere in the system Remarque Avec un tra...

Page 12: ...hird line Consult the transformer manufacturer s literature to be sure the single leg can supply the required power Attention Avec la connexion en triangle une borne doit tre centre tapped et seulemen...

Page 13: ...lug head is connected by one foot of cable to the bottom side of the EV40P The charger must be positioned such that the plug can safely be inserted into a wall mounted NEMA socket The plug in EV40P is...

Page 14: ...intering while the screw is fastened The included plastic angle washers can be oriented to allow the lag screws to be fastened at an angle while still providing a solid flat backing to the screw head...

Page 15: ...d Select those washers that best accommodate the mounting hardware angle of attack and orient them accordingly If the head of the mounting hardware is smaller than the 3 8 plastic angle washer apertur...

Page 16: ...on the mounting surface The vertical alignment of the EV40 and SAE J1772 connector holster mounting holes allows for the convenient mounting of both components onto the same post or wall structure For...

Page 17: ...titled Service Connections on page 6 If you are unsure of the type of power provided at the service panel please consult with you local utility or call your service representative for assistance Note...

Page 18: ...it will not fit in the outlet have a proper outlet installed Attention Une mauvaise connexion du conducteur de terre peut entra ner un risque de choc lectrique V rifier avec un lectricien qualifi si...

Page 19: ...c ble du connecteur de charge EV 1 Eteignez la quipement au disjoncteur avant de le nettoyer 2 Nettoyez votre quipement l aide d un chiffon doux l g rement humidifi avec une solution de d tergent dou...

Page 20: ...264V AC Frequency 60 Hz Current Output Power at 240VAC Circuit Maximum Output EV40 Model Breaker Current Power EV40 Hardwired 40A 30A 7 2KW EV40P 14 50 plug 50A 30A 7 2KW Note that the maximum curren...

Page 21: ...will at its option repair or replace the product Repair parts and or replacement products may be either new or reconditioned at Sun Country Highway s discretion This limited warranty does not cover s...

Page 22: ...t will be provided If you mail or ship the product in for service you must insure the product prepay all shipping charges and properly pack it for shipment in its original shipping container or its eq...

Page 23: ...EV40 User s Manual Page 20 Sun Country Highway 306 Saskatchewan Crescent Saskatoon SK S7N 0K6 1 866 467 1371 info suncountryhighway ca...