9
test new and exchanged LP tanks BEFORE connecting to burner.
-
Always check the rating plate to make sure the gas supply you are hooking up to is the gas type the side
burner is manufactured for.
This natural gas burner is designed to operate on natural gas ONLY, at a pressure regulated at 4”
(101.6mm) water column (W.C.) when equipped with the correct natural gas orifices on the valves and a
natural gas regulator on the supply line regulated at the residential meter.
IMPORTANT:
Never connect the burner to an unregulated gas supply.
Natural gas connections must be performed by a licensed contractor or local gas company
representative.
Hose and Regulator
IMPORTANT: NEVER
use side burner without leak testing this
connection.
Natural gas regulator model: GR120N
Gas pressure: 4” (101.6mm)
Quick disconnect model: 1/2QDD-DK
Gas hose connector model: CFN12
Maximum rate working pressure: 1/2 Psig
Natural Gas Supply Connection and Disconnection
1. Make sure all burner valves are in the “OFF” position.
2. To connect-push back sleeve of socket, insert Plug release sleeve. Push Plug until sleeve snaps
forward locking Plug in Socket. (THIS TURNS GAS AUTOMATICALLY).
3. To disconnect: Push sleeve back and pull out plug. (THIS AUTOMATICALLY SHUTS OFF GAS)
4. Connected hose assembly shall be of adequate length and capacity for intended application. Final
assembly must be tested for leaks.
Natural Gas Hook-up