To Assemble the Power Inlet and Leads
1. Insert the socket in the appropriate slot on the motherboard.
The socket can only be inserted one way round. The label on the front of the filter
indicates the correct orientation.
2. Tighten the captive spring-loaded screws, preferably finger-tight only.
If you use a screwdriver, these screws should be tightened no more than 6 in-lbf
(0.68 Nm). Refer to
FIGURE 3-5
.
FIGURE 3-5
Power Connector Wiring Polarity and Securing Screws
3. Strip 9mm of insulation from boths ends of each power lead.
The connectors will not accommodate leads of greater than 8 AWG (6 mm
2
).
–
Negative A
–
Negative B
+
RETURN B
+
RETURN A
Inlet filter
securing
screws