Chapter 4
Replacing Cold Swappable FRUs
97
b. Remove the fan guard from the chassis.
5. Disconnect the front I/O board data cable.
6. Remove the LED board. See
“To Remove the LED Board” on page 93
.
7. Remove the screw that secures the front I/O board to the chassis.
8. Slide the front I/O board back, tilt it up, clear the two mounting tabs in the front,
and lift it straight out of the chassis (
FIGURE 4-24
).
FIGURE 4-24
Removing the Front I/O Board
9. Place the front I/O board on an antistatic mat.
▼
To Replace the Front I/O Board
1. Unpackage the front I/O board and place it on an antistatic mat.
2. Tip the front I/O board downwards and slightly forward and push it into place,
aligning the board with the screw hole in the exterior wall of the chassis.
When the board is fully seated, both connectors on the USB ports are mounted flush
against the motherboard assembly.
3. Using the screw, secure the front I/O board to the chassis.
4. Reconnect the front I/O board data cable.