A-2
SPARCstation 4 Model 110 Service Manual • July 1996
A.2
Input Power Requirements
TABLE A-2
lists the input power requirements for the SPARCstation 4 system.
TABLE A-3
lists the input power requirements for the SPARCserver 4 system.
TABLE A-2
Input Power Requirements and Power Dissipation—SPARCstation 4 System
Parameter
Specification
Nominal Frequencies
50 Hz or 60 Hz nominal
Nominal Voltage Range
100-120 Vac or 200-240 Vac
(100-240 Vac Auto)
Maximum Current AC RMS
1
1. Maximum input current with accessory connected to accessory outlet is 6 A.
0.75 A @ 100-120 Vac, 0.375 A @
200-240 Vac
AC Operating Range
87-264 Vrms, 47-63 Hz
Maximum VA Rating
75 VA
Maximum Power Consumption
2
2. Maximum power consumption with monitor connected to accessory outlet is 203 Watts.
53 Watts
Maximum Heat Output
180.8 BTU/hr
TABLE A-3
Input Power Requirements and Power Dissipation—SPARCserver 4 System
Parameter
Specification
Nominal Frequencies
50 Hz or 60 Hz nominal
Nominal Voltage Range
100-120 Vac or 200-240 Vac
(100-240 Vac Auto)
Maximum Current AC RMS
1
1. Maximum input current with accessory outlet is 6A.
1.0 A @ 100-120 Vac, 0.5 A @
200-240 Vac
AC Operating Range
87-264 Vrms, 47-63 Hz
Maximum VA Rating
100 VA
Maximum Power Consumption
2
2. Maximum power consumption with monitor connected to accessory outlet is 249 Watts.
99 Watts
Maximum Heat Output
337.0 BTU/hr
Summary of Contents for SPARCstation 4 110
Page 24: ...1 6 SPARCstation 4 Model 110 Service Manual July 1996...
Page 36: ...2 12 SPARCstation 4 Model 110 Service Manual July 1996...
Page 46: ...3 10 SPARCstation 4 Model 110 Service Manual July 1996...
Page 108: ...10 4 SPARCstation 4 Model 110 Service Manual July 1996...
Page 146: ...12 6 SPARCstation 4 Model 110 Service Manual July 1996...
Page 150: ...A 4 SPARCstation 4 Model 110 Service Manual July 1996...
Page 160: ...B 10 SPARCstation 4 Model 110 Service Manual July 1996...
Page 174: ...Glossary 4 SPARCstation 4 Model 110 Service Manual July 1996...