Appendix D
FORTH Diagnostics
D-7
D.1.5
probe-scsi, probe-scsi-all
The probe-scsi test sends an inquiry command to internal and external SCSI devices
connected to the system’s internal SCSI interface. If a SCSI device is connected and
powered up, the target address, unit number, device type, and manufacturer name
should be displayed.
For example:
The
probe-scsi-all
test sends an inquiry command to all SCSI devices on all the
SCSI host adapters installed in the system. The first identifier listed in the display is
the SCSI host adapter address in the system device tree, followed by the SCSI device
identification data.
For example:
D.1.6
module-info
This command reports back the system CPU information including: the
microprocessor name, its revision, the speed at which it is running in megahertz,
and the SBus speed in megahertz.
For example:
ok probe-scsi
Target 3
Unit 0 Disk SEAGATE ST1480 SUN04245828 Copyright (c) 1991 Seagate All rights
reserved.
ok probe-scsi-all
/iommu@0,100000000/sbus@0,10001000/espdma@5,8400000/esp@5,8800000
Target 1
Unit 0 Disk CONNER CP30548 SUN0535AEBX93081QTT
Target 3
Unit 0 Disk CONNER CP30548 SUN0535AEBX93081QTT
Target 6
Unit 0 Removable Read Only device TOSHIBA CD-ROM XM-4101TA289310/16/93
ok module-info
CPU FMI,MB86904 Rev. 2.0: 70.0 Mhz
SBus (Divide By 3)
: 23.3 Mhz
ok
Summary of Contents for SPARCstation 4 110
Page 24: ...1 6 SPARCstation 4 Model 110 Service Manual July 1996...
Page 36: ...2 12 SPARCstation 4 Model 110 Service Manual July 1996...
Page 46: ...3 10 SPARCstation 4 Model 110 Service Manual July 1996...
Page 108: ...10 4 SPARCstation 4 Model 110 Service Manual July 1996...
Page 146: ...12 6 SPARCstation 4 Model 110 Service Manual July 1996...
Page 150: ...A 4 SPARCstation 4 Model 110 Service Manual July 1996...
Page 160: ...B 10 SPARCstation 4 Model 110 Service Manual July 1996...
Page 174: ...Glossary 4 SPARCstation 4 Model 110 Service Manual July 1996...