background image

-10

Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide • May 2002

1.5

Testing the Installation

1.5.1

SunVTS

Refer to the SunVTS documents in

TABLE 1-1

on page 1-10.

SunVTS is a diagnostic program that exercises your system to verify the
functionality, reliability, and configuration of your Network Adapter. You will need
to install both the 32- and 64-bit versions of SunVTS.

1.5.2

Testing Procedure

1. To invoke SunVTS locally on a system running CDE, type the following as

root

:

2. From the SunVTS menus select the following:

a. Select devices

None

and select

intervention

.

b. Select mode

Functional test

.

c. Select

Host Adapter qlcx

where

x

is the qlc number of the

qlc

port you want

to run this test against.

d. If you want to run the external loopback test, place a loopback plug into the qlc

port that you want to test.

If you do not have an external loopback plug, you can make one by taking apart
a fiber cable and plug the same cable into the transmitter and receiver of the qlc
port.

TABLE 1-1

Sun VTS Documents

Application

Title

Part Number

Diagnostic Testing

SunVTS 4.5 User’s Guide

816-1575

SunVTS 4.5 Test Reference

816-1576

cd /opt/SUNWvts/bin

./sunvts

Summary of Contents for StorEdge X6767A

Page 1: ...Network Circle Santa Clara CA 95054 U S A 650 960 1300 Send comments about this document to docfeedback sun com Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide Part No 816 49...

Page 2: ...2002 Sun Microsystems Inc 901 San Antonio Road Palo Alto CA 94303 4900 Etats Unis Tous droits r serv s Ce produit ou document est prot g par un copyright et distribu avec des licences qui en restreig...

Page 3: ...ntation 5 Accessing Sun Documentation Online 5 Sun Welcomes Your Comments 5 3 Installation 1 1 1 1 Software Requirements 1 1 1 1 1 Device Drivers 1 1 1 2 Tools and Equipment Needed 1 2 1 3 Preparing f...

Page 4: ...finitions 32 Bit Cards 5 5 A 8 PCI X Edge Connector Pin Definitions 64 Bit Cards 5 7 B Booting From the Network Adapter 6 1 B 1 The Net Install Method 6 2 B 1 1 Overview For the Net Install Method 6 2...

Page 5: ...not approved by Sun Microsystems Inc may void the authority granted to the user by the FCC to operate this equipment FCC Class B Notice This device complies with Part 15 of the FCC Rules Operation is...

Page 6: ...A This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada ICES 003 Class B Notice Avis NMB 003 Classe B This Class...

Page 7: ...vii This page is intentionally left blank...

Page 8: ...viii Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002 This page is intentionally left blank...

Page 9: ...may be used Modifications to Equipment Do not make mechanical or electrical modifications to the equipment Sun Microsystems is not responsible for regulatory compliance of a modified Sun product Plac...

Page 10: ...ectric shock always plug the cord into a grounded power outlet Caution The power switch of this product functions as a standby type device only The power cord serves as the primary disconnect device f...

Page 11: ...le Die Symbole in diesem Handbuch haben folgende Bedeutung Je nach Netzschaltertyp an Ihrem Ger t kann eines der folgenden Symbole benutzt werden Nehmen Sie keine mechanischen oder elektrischen nderun...

Page 12: ...Netzsteckdosen geliefert Um die Gefahr eines Stromschlags zu reduzieren schlie en Sie das Kabel nur an eine fachgerecht verlegte geerdete Steckdose an Achtung Der Ein Aus Schalter dieses Ger ts schalt...

Page 13: ...onducteur introduit de la sorte pourrait produire un court circuit qui entra nerait des flammes des risques d lectrocution ou des d g ts mat riels Symboles Vous trouverez ci dessous la signification d...

Page 14: ...En cas de doute quant au type d alimentation lectrique du local veuillez vous adresser au directeur de l exploitation ou un lectricien qualifi Attention tous les cordons d alimentation n ont pas forc...

Page 15: ...as el ctricas o da os en el equipo S mbolos En este libro aparecen los siguientes s mbolos Attention Les unit s Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide contiennent une...

Page 16: ...Sun y para protegerlo de sobrecalentamien tos no deben obstruirse o taparse las rejillas del equipo Los productos Sun nunca deben situarse cerca de radiadores o de fuentes de calor Precauci n De acuer...

Page 17: ...tada en el reloj de tiempo real tipo SGS N m MK48T59Y MK48TXXB XX MK48T18 XXXPCZ M48T59W XXXPCZ o MK48T08 Las bater as no son elementos reemplazables por el propio cliente Pueden explotar si se manipu...

Page 18: ...a vid felaktigt batteribyte Anv nd samma batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren Kassera anv nt batteri enligt fabrikantens instruktion ADVARSEL Litiumbatteri Ekspl...

Page 19: ...ines 10m EN61000 4 6 3 V EN61000 4 11 Pass As Information Technology Equipment ITE Class B per EN55022 1998 CISPR22 1997 Class B EN55024 1998 Required Limits as applicable EN61000 4 2 4 kV Direct 8 kV...

Page 20: ......

Page 21: ...nistrator or trained service provider Using UNIX Commands This document may not contain information on basic UNIX commands and procedures such as shutting down the system booting the system and config...

Page 22: ...u have mail AaBbCc123 What you type when contrasted with on screen computer output su Password AaBbCc123 Book titles new words or terms words to be emphasized Command line variable replace with a real...

Page 23: ...ed in improving its documentation and welcomes your comments and suggestions You can email your comments to Sun at docfeedback sun com Please include the part number of your document in the subject li...

Page 24: ...6 Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002...

Page 25: ...I Single Channel Network Adapter is Solaris 8 10 01 update 6 All of the drivers are unbundled with Solaris 8 See the Sun StorEdge 2G FC PCI Single Channel Network Adapter Product Notes for a list of t...

Page 26: ...un StorEdge 2G FC PCI Single Channel Network Adapter Product Notes to download the Fibre Channel transport device driver patches or for updates go to http sunsolve sun com 1 2 Tools and Equipment Need...

Page 27: ...ialized during POST power on self test nor will it subsequently be recognized by the operating system FIGURE 1 1 JTAG Jumper 1 3 2 Preparing for a Sun StorEdge A5x00 Installation 1 Use the array s fro...

Page 28: ...not have an etc release file you probably need to upgrade you operating environment to at least Solaris 8 3 Get the required software qlc driver SunVTS a Go to the http www sun com products n solution...

Page 29: ...tion provides the ground path necessary to remove and install printed circuit boards and components without damage 8 Choose a slot into which to install the Network Adapter Follow the procedures in th...

Page 30: ...transceiver OT connector FIGURE 1 3 FIGURE 1 3 Sun StorEdge PCI Single 2G Fibre Channel Network Adapter Dust Covers 2 Install the Network Adapter in the PCI slot you have chosen Installation details v...

Page 31: ...ame with the device for specific instructions 7 Power on your peripherals and then your system Note When you power on the system the LED lights on the host bus adapter might blink The LEDs are intende...

Page 32: ...b 2000 pci b 4000 counter timer a 1c00 fhc a f8800000 pci a 2000 pci a 4000 counter timer 3 3c00 sbus 3 0 counter timer 2 3c00 fhc 2 f8800000 sbus 2 0 SUNW UltraSPARC II 7 0 SUNW UltraSPARC II 6 0 fhc...

Page 33: ...03FSUN18G 114A 44 6c 0 21000020376501bf SEAGATE ST318304FSUN18G 012D 45 6b 0 21000020376502fa SEAGATE ST318304FSUN18G 012D 46 6a 0 2100002037651a7e SEAGATE ST318304FSUN18G 0726 4d 5a 0 508002000002f23...

Page 34: ...ng as root 2 From the SunVTS menus select the following a Select devices None and select intervention b Select mode Functional test c Select Host Adapter qlcx where x is the qlc number of the qlc port...

Page 35: ...o storage devices In such a case you will be testing both the qlc and the entire fiber loop g Select Start to start the test Note If you select only the external loopback test the different version di...

Page 36: ...12 Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002...

Page 37: ...Channel Interface Specifications TABLE A 1 Fibre Channel Specifications Specification Value ANSI Standards Fibre Channel FC PH X3 230 1995 SCSI Fibre Channel Protocol X3 269 1996 Optical transceiver...

Page 38: ...BLE A 2 Performance Specifications Feature Specification PCI clock 66 MHz maximum PCI data burst transfer rate 528 MBytes sec burst rate FC AL transfer rate payload 200 MBytes sec PCI data address lin...

Page 39: ...A 5 Physical Dimensions TABLE A 3 Power Requirements Specification Rating Voltage and current 5V 5 3A Ripple 100 mV TABLE A 4 Physical Dimensions Height Width Depth Weight 15 mm 106 68 mm 174 63 mm 10...

Page 40: ...pliance TABLE A 5 Requirements Met or Exceeded by the Network Adapter Category Rating Safety UL 1950 CSA 950 TUV EN 60950 Class 1 laser requirements per CFR 21 Part 1040 and IEC 825 RFI EMI FCC Class...

Page 41: ...AD14 4 TDO 25 3 3V 46 GND 5 5V 26 C_BE3 47 AD12 6 5V 27 AD23 48 AD10 7 INTB 28 GND 49 GND 8 INTD 29 AD21 50 KEYWAY 9 GND PRSNT1 30 AD19 51 KEYWAY 10 RESERVED 31 3 3V 52 AD08 11 GND PRSNT2 32 AD17 53 A...

Page 42: ...3 TMS 24 GND 45 3 3V 4 TDI 25 AD24 46 AD13 5 5V 26 IDSEL 47 AD11 6 INTA 27 3 3V 48 GND 7 INTC 28 AD22 49 AD09 8 5V 29 AD20 50 KEYWAY 9 RESERVED 30 GND 51 KEYWAY 10 5V 31 AD18 52 C_BE0 11 RESERVED 32 A...

Page 43: ...NTD 5V 33 C BE 2 3 3V 9 PRSNT1 Reserved 34 Ground FRAME 10 Reserved VI O 35 IRDY Ground 11 PRSNT2 Reserved 36 3 3V TRDY 12 Keyway Keyway 37 DEVSEL Ground 13 Keyway Keyway 38 Ground STOP 14 Reserved 3...

Page 44: ...d 81 AD 45 Ground 57 Ground AD 02 82 Ground AD 44 58 AD 01 AD 00 83 AD 43 AD 42 59 VI O VI O 84 AD 41 VI O 60 ACK64 REQ64 85 Ground AD 40 61 5V 5V 86 AD 39 AD 38 62 5V 5V 87 AD 37 Ground Keyway Keyway...

Page 45: ...erience complications in the loss of the boot However the method is available to anyone with existing systems whether small or large configurations and it provides a disk image when you have completed...

Page 46: ...nstall server 1 Therefore the convention used in this chapter is to refer to either type of server as the boot install server B 1 1 Overview For the Net Install Method Installing a client from a boot...

Page 47: ...the boot install server the interactive suninstall 1M application starts and the system administrator provides configuration information requested at the prompts 4 After the system administrator provi...

Page 48: ...this network adapter as instructed in the README d Download the packages as described in the instructions in the release notes e Use the uncompress 1M and tar 1M commands to uncompress and expand the...

Page 49: ...es You must follow this order for a successful installation so the driver will run 2 Install any needed patches into the boot image The following example installs any patch es that were previously dow...

Page 50: ...Caution Do not reboot the boot install server 2 Boot the host from the net The Solaris interactive installation program runs from the boot install server 3 Respond to the prompts according to your con...

Page 51: ...alls all packages previously downloaded into the export_public directory When prompted install the packages in the order of SUNWsan SUNWcfpl SUNWcfplx 7 Install any needed patches into the boot image...

Page 52: ...nnected at least temporarily to the host The boot disk must have the following installed The Solaris operating environment The network adapter driver packages and any needed patches See the release no...

Page 53: ...ad center and install it on the host following the instructions in the README file that comes with the driver To download the driver follow the instructions in the release notes 3 Reboot using the reb...

Page 54: ...screen example specifies disk 2 format Searching for disks done AVAILABLE DISK SELECTIONS 0 c0t1d0 SUN18G cyl 7506 alt 2 hd 19 sec 248 pci 8 600000 SUNW qlc 4 fp 0 0 ssd w2100002037e43542 0 1 c0t2d0...

Page 55: ...hange 7 partition select select a predefined table modify modify a predefined partition table name name the current table print display the current table label write partition map and label to the dis...

Page 56: ...rmat prompt type disk to change the current disk to the new boot disk partition quit FORMAT MENU disk select a disk type select define a disk type partition select define a partition table current des...

Page 57: ...s specify the root slice 0 on the new boot disk to match slice 0 on the temporary boot disk format disk 2 selecting c7t16d0 disk formatted FORMAT MENU disk select a disk type select define a disk type...

Page 58: ...tition select select a predefined table modify modify a predefined partition table name name the current table print display the current table label write partition map and label to the disk cmd execu...

Page 59: ...w starting cylinder The following example shows the default new starting cylinder of 0 accepted by pressing the Return key 6 Enter the partition size The following example shows the partition size of...

Page 60: ...Part Tag Flag Cylinders Size Blocks 0 root wm 0 1451 2 00GB 1452 0 0 4194828 1 swap wu 91 181 128 37MB 91 0 0 262899 2 backup wu 0 24619 33 92GB 24620 0 0 71127180 3 unassigned wm 0 0 0 0 0 0 4 unassi...

Page 61: ...fy the slices on the new boot disk label the new boot disk with the new partition table 1 Enter the label command 2 Enter y es to continue 3 When the labeling is complete enter q uit to quit the forma...

Page 62: ...b procedures including Section B 2 4 1 To Copy the Boot Block and Root File System Contents To the New Boot Disk on page B 19 Section B 2 4 2 To Update the vfstab File on page B 20 Section B 2 4 3 To...

Page 63: ...mount point 3 Use the ufsdump 1M and ufsrestore 1M commands to copy the contents of the root file system from the temporary boot disk to the root slice of the new boot disk on the mnt mount point usr...

Page 64: ...file for editing The following example shows the file systems defined 3 Replace the name of the temporary boot disk with the name of the new boot disk and then save and quit the file The following exa...

Page 65: ...contents to the new boot disk When finished go to Section B 2 4 2 To Update the vfstab File on page B 20 mount dev dsk c7t16d0 mnt ufsdump 0f dev rdsk c0t0d0s0 cd mnt ufsrestore rf DUMP Writing 32 Kil...

Page 66: ...ce name of the disk to a short name for the disk The following example uses pci 8 600000 SUNW qlc 1 fp 0 0 disk 10 0 which was the device path name for disk 2 in Section B 2 2 2 To Record the Partitio...

Page 67: ...Appendix 23 5 Enter the boot command with the r option so that the Solaris operating environment can recognize the adapter ok boot r...

Page 68: ...24 Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002...

Reviews: