-6
Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide • May 2002
Note –
You can find the platform name by running the
uname
command with the
-m
option on the host that has the host adapter.
5. Log out of the boot/install server.
B.1.4
To Set Up the Client
1. Bring the client host (with the host adapter) down to the
ok
prompt at run level 0.
See the Solaris system administration documentation for the commands that can be
used with different configurations. The following example uses the
shutdown
(1M)
command.
Caution –
Do not reboot the boot/install server.
2. Boot the host from the net.
The Solaris interactive installation program runs from the boot/install server.
3. Respond to the prompts according to your configuration, as instructed in the
Solaris installation guide.
Make sure to specify the new boot disk as the destination for the operating
environment installation.
4. When prompted to choose between automatic reboot or manual reboot, click the
Manual Reboot button, complete the remaining question, and start the
installation.
This question offering a choice between automatic and manual reboot is the last
question before the installation starts. If you are using the
suninstall
program,
choose
boot manual
.
# shutdown
...
ok
ok boot net
Summary of Contents for StorEdge X6767A
Page 7: ...vii This page is intentionally left blank...
Page 20: ......
Page 24: ...6 Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002...
Page 36: ...12 Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002...
Page 68: ...24 Sun StorEdge 2G FC PCI Single Channel Network Adapter Installation Guide May 2002...