Chapter 13
Replacing Chassis Components
13-17
2. Locate the rear fan.
The rear fan is housed in a green plastic bracket that connects to the workstation
chassis. See
.
3. Remove the DIMM cooling duct.
Refer to
“Removing the DIMM Cooling Duct” on page
4. Disconnect the rear fan cable from the motherboard connector
FAN1 SYS
.
See
FIGURE
13-15
Rear Fan Motherboard Connection
5. Lift the rear fan bracket latch while sliding the fan bracket down the chassis.
See
Connector
FAN1 SYS