Chapter 4
Troubleshooting
Flowcharts
4-9
4.2.3
System Fan Problem
FIGURE
4-6
System Fan Problem
There is a problem with
the system fans.
The system fans are ther-
mally controlled and only
turn on when cooling is
needed.
Is the room
temperature greater than
15
°
C (60
°
F)?
Is the rear fan
spinning?
Is the
rear fan exceptionally
noisy?
Check the rear fan and
replace if necessary. See
“Replacing the Rear Fan”
on page
Is the front fan
spinning?
Check the front fan and
replace if necessary. See
“Replacing the Front Fan”
on page
Is the
front fan exceptionally
noisy?
“Replacing the Rear Fan”
on page
.
Is the CPU fan
spinning?
Check CPU fan and
replace if necessary. See
“Replacing the CPU Fan
and Heat Sink Assembly”
on page
Is the
CPU fan exceptionally
noisy?
“Replacing the Front Fan”
on page
.
Replace the CPU fan and
heat sink. See
ing the CPU Fan and Heat
Sink Assembly” on
page
Y
N
Y
N
Y
N
Y
N
Y
N
Y
N
Y
N
In normal operation, the system fan’s speed is set accord-
ing to the temperature inside of the workstation. If it is
cold, the fans might not turn on at all and instead make a
quiet grumbling sound.
When fan bearings fail, they have a distinct noisy sound
and the fan should be replaced. Do not mistake this for the
full fan speed sound at power on.
If might be difficult to hear the CPU fan spinning.
Checking a component means checking the electrical con-
nections and fit.
Summary of Contents for Sun Blade 1500
Page 16: ...xvi Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 30: ...xxx Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 40: ...xl Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 186: ...8 22 Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 360: ...13 62 Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 412: ...A 4 Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 432: ...B 20 Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 472: ...C 40 Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...
Page 500: ...Index 14 Sun Blade 1500 Service Diagnostics and Troubleshooting Manual December 2004...