4-58
Sun Fire B1600 Blade System Chassis Switch Administration Guide • June 2003
Syntax
snmp-server host
host-addr community-string
version
version-number
no snmp-server host
host-addr
■
host-addr
– Name or Internet address of the host (the targeted recipient).
(Maximum host addresses: 5 trap destination IP address entries)
■
community-string
– Password-like community string sent with the notification
operation. Though you can set this string using the
snmp-server host
command
by itself, we recommend you define this string using the
snmp-
server community
command prior to using the
snmp-server host
command. (Maximum length: 32 characters)
■
version-number
– {
1
|
2c
}
■
Indicates if the host is running SNMP version 1 or version 2c.
Default Setting
None
Command Mode
Global Configuration
Command Usage
■
If you do not enter an
snmp-server host
command, no notifications are
sent. In order to configure the switch to send SNMP notifications, you must
enter at least one
snmp-server host
command. In order to enable multiple
hosts, you must issue a separate
snmp-server host
command for each host.
■
The
snmp-server host
command is used in conjunction with the
snmp-
server enable traps
command. Use the
snmp-server enable traps
command to specify which SNMP notifications are sent globally. For a host to
receive notifications, you must enter at least one
snmp-server enable
traps
command and the
snmp-server host
command for that host.
■
Some notification types cannot be controlled with the
snmp-server enable
traps
command. For example, some notification types are always enabled.
Example
Console(config)#
snmp-server host 10.1.19.23 batman version 1
Console(config)#
Summary of Contents for Sun Fire B1600 Administration
Page 4: ......
Page 17: ...Contents xvii Glossary Glossary 1 Index Index 1 ...
Page 18: ...xviii Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 38: ...2 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 47: ...Chapter 3 General Management of the Switch 3 9 FIGURE 3 3 Switch Setup System Identity Window ...
Page 198: ...3 160 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 372: ...A 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 392: ...C 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 398: ...Glossary 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide April 2003 ...
Page 402: ...Index 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide January 2003 ...