4-170
Sun Fire B1600 Blade System Chassis Switch Administration Guide • June 2003
Example
The following shows LACP enabled on ports NETP0 to NETP2. Because LACP
has also been enabled on the ports at the other end of the links, the
show
interfaces status port-channel 1
command shows that port-channel 1
has been established.
Console(config)#
interface ethernet NETP0
Console(config-if)#
lacp
Console(config-if)#
exit
Console(config)#
interface ethernet NETP1
Console(config-if)#
lacp
Console(config-if)#
exit
Console(config)#
interface ethernet NETP2
Console(config-if)#
lacp
Console(config-if)#
exit
Console(config)#
exit
Console#
show interfaces status port-channel 1
Information of Trunk 1
Basic information:
Port type: 1000t
Mac address: 00-00-e8-00-00-0b
Configuration:
Name:
Port admin status: Up
Speed-duplex: Auto
Capabilities: 10half, 10full, 100half, 100full, 1000full
Flow control status: Disabled
Current status:
Created by: lacp
Link status: Up
Operation speed-duplex: 1000full
Flow control type: None
Member Ports: NETP0, NETP1, NETP2,
Console#
Summary of Contents for Sun Fire B1600 Administration
Page 4: ......
Page 17: ...Contents xvii Glossary Glossary 1 Index Index 1 ...
Page 18: ...xviii Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 38: ...2 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 47: ...Chapter 3 General Management of the Switch 3 9 FIGURE 3 3 Switch Setup System Identity Window ...
Page 198: ...3 160 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 372: ...A 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 392: ...C 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide June 2003 ...
Page 398: ...Glossary 6 Sun Fire B1600 Blade System Chassis Switch Administration Guide April 2003 ...
Page 402: ...Index 4 Sun Fire B1600 Blade System Chassis Switch Administration Guide January 2003 ...