1. Scope of application 

This Installation Manual is suit for the Fiber Optic Splice Closure (Hereafter 

abbreviated as FOSC), as the guidance of proper installation. The scope of 

application is: aerial, underground, pipeline, handhole.   

2. Applicable temperature 

 

-1

+45

(Temperature for operation) 

 

-50

+70

(Temperature for storage and transportation) 

 

-40

+65

(The ambient temperature ranges) 

3. Stripping fiber cable   

3.1

 When branch cable stripping, should put the length of the fiber optic cable 

skin peeled off as about 1200 mm, Reserve reinforced core in 60 mm length 

and cut off the unnecessary ones. See figure 1 

 

             

 

3.2 

When straight-through cable stripping, should put the length of the fiber 

optic cable skin peeled off as about 1600 mm, Reserve reinforced core in 60 

mm length and cut off the unnecessary ones. See figure 2 

 

4. Fixing fiber cable. 

4.1

  Fixed  cable  and  heat  shrinkable  fixing  sleeve  according  to  the  picture 

below. See figure 3, figure5.   

 

 

 

 

1200

mm 

Figure 1 

 

1600

mm 

Figure 2 

 

Figure 3 

 

Summary of Contents for SUN-FOSC-ZT702 Series

Page 1: ... FOSC ZT702 Series Fiber Optic Splice Closure Table SUN UM CM FOSC002 Version A 0 All the trademarks mentioned in this manual are registered property of Sun Telecom The right to interpret this manual is reserved by Sun Telecom ...

Page 2: ...The ambient temperature ranges 3 Stripping fiber cable 3 1 When branch cable stripping should put the length of the fiber optic cable skin peeled off as about 1200 mm Reserve reinforced core in 60 mm length and cut off the unnecessary ones See figure 1 3 2 When straight through cable stripping should put the length of the fiber optic cable skin peeled off as about 1600 mm Reserve reinforced core i...

Page 3: ...hrinkable sleeve for splice protection 4 3 Check up comprehensively To ensure the technical requirements the following instructions must be followed Fibers with protective coat are fixed with nylon tie at the entrance of FOST Grommet should be pressed from inside to outside in order to properly install FOST If there are fibers with protective coat reserved wind it into the fiber holding tray Check...

Page 4: ... once more 6 The installation and fixed of FOSC 6 1 Aerial application Fix metal hoop and transom to the pole Please refer to figure 6 6 2 Wall mounting application Fix the bracket on the wall with the bolt Metal hoop is not required See figure 7 6 3 Underground application Metal hoop is not required wall accessories SHANGHAI SUN TELECOMMUNICATION CO LTD Building No 145 Lane 666 Xianing Rd Jinshan...

Reviews: