4.2 

Splice fibers, install heat shrinkable protective sleeve

     

See figure 4 follow user manual of fusion splicing machine to splice fiber 

cores. When having completed splicing the fibers, the first fiber ring should 

be housed on the farthest side of FOST, the remaining fiber should be winded, 

forming a ring with diameter not less than 80mm. then put it into FOST (Fiber 

Optic Splice Tray).together with heat shrinkable sleeve for splice protection. 

           

             

 

4.3 

Check up comprehensively

   

To  ensure  the  technical  requirements,  the  following  instructions  must  be 

followed: 

 

Fibers  with  protective  coat  are  fixed  with  nylon  tie  at  the  entrance  of 

FOST. 

 

Grommet should be pressed from inside to outside  in order to properly 

install FOST. 

 

If  there  are  fibers  with  protective  coat  reserved,  wind  it  into  the  fiber 

holding tray.   

 

Check  whether  the  internal  tighteners  and  reinforced  core  are  well 

tightened. 

 

Check whether gasket ring is installed neatly and smoothly without any 

breakage. If not, level it up with seal tape.   

Important issues: 

If any problems occur, they should be solved right away. 

See figure 5 

Figure 4 

 

Figure 5 

 

Summary of Contents for SUN-FOSC-ZT702 Series

Page 1: ... FOSC ZT702 Series Fiber Optic Splice Closure Table SUN UM CM FOSC002 Version A 0 All the trademarks mentioned in this manual are registered property of Sun Telecom The right to interpret this manual is reserved by Sun Telecom ...

Page 2: ...The ambient temperature ranges 3 Stripping fiber cable 3 1 When branch cable stripping should put the length of the fiber optic cable skin peeled off as about 1200 mm Reserve reinforced core in 60 mm length and cut off the unnecessary ones See figure 1 3 2 When straight through cable stripping should put the length of the fiber optic cable skin peeled off as about 1600 mm Reserve reinforced core i...

Page 3: ...hrinkable sleeve for splice protection 4 3 Check up comprehensively To ensure the technical requirements the following instructions must be followed Fibers with protective coat are fixed with nylon tie at the entrance of FOST Grommet should be pressed from inside to outside in order to properly install FOST If there are fibers with protective coat reserved wind it into the fiber holding tray Check...

Page 4: ... once more 6 The installation and fixed of FOSC 6 1 Aerial application Fix metal hoop and transom to the pole Please refer to figure 6 6 2 Wall mounting application Fix the bracket on the wall with the bolt Metal hoop is not required See figure 7 6 3 Underground application Metal hoop is not required wall accessories SHANGHAI SUN TELECOMMUNICATION CO LTD Building No 145 Lane 666 Xianing Rd Jinshan...

Reviews: