A.6
Environmental Specifications
TABLE A-8
lists the environmental specifications for the Sun Ultra 20 M2 Workstation.
TABLE A-8
Sun Ultra 20 M2 Workstation Environmental Specifications
Specification
State
British
Metric
Humidity
Operating
7%–93% RH noncondensing,
100.4˚ F max wet bulb
7%–93% RH noncondensing,
38˚ C max wet bulb
Nonoperating
93% RH, noncondensing,
109.4˚ F max wet bulb
93% RH, noncondensing,
43˚ C max wet bulb
Vibration
Operating
0.25G in all axes, 5–500 Hz sine
Nonoperating
1.2G in all axes, 5–500 Hz sine
Shock
Operating
4.5G, 11 msec. half-sine
Temperature
Operating
41˚ F to 95˚ F
5˚ C to 35˚ C
Nonoperating
–40˚ F to 149˚ F
–40˚ C to 65˚ C
Maximum
operating
temperature
rating
–1.8˚ F for every 985 ft in altitude
–1˚ C for every 300 m in altitude
Altitude
Operating
max 9,843 ft
max 3,000 m
Nonoperating
max 39,370 ft
max 12,000 m