FIRE HAZARD

 

through contact of 

accumulated waste (dry leaves, 

plastic  bags,  paper)  with  the 

hot parts of the collectors. We 

recommend the regular inspection 

and cleaning of collector installation 

sites.

DANGER of slipping, fall. 

In 

most cases, collectors are 

installed in hardly accessible and 

dangerous places. We recommend 

that  installation  and  service 

maintenance be carried out by 

authorized service technicians 

observing all safety measures.

1.2.2. 

Instructions to installation user

CAUTION! Danger of injury 

/ damage of system due to 

incompetent operation.

-

 

The solar collector must be 

serviced only by persons familiar 

with the operation manual.

-

 

Structural changes to collector 

by user can cause damage to 

equipment or injury.

Safety rules for user operation:

- The  solar  collector  can  be  used  to 

produce  hot  water  and  support  the 

heating  system  only  in  the  manner 

described in this manual.

- Installation  and  maintenance  must  be 

performed by a technician / service shop 

authorized for such operations.

2. DESCRIPTION OF PK TYPE FLAT-PLATE 

COLLECTOR

2.1. 

Absorber coating

Diagram 1.

The  heart  of  each  solar  collector  –  the 

absorber – is the key factor for the overall 

performance of the unit. 

Made entirely of 

copper tubes and copper sheets. Copper 

sheets  join  copper  pipe  with  ultrasonic 

welding and silver soldering.

Model 

PK Standard CL

 

absorber  is  with 

Black  solar  coating

PK Standard CL

 

collectors 

are  an  ecological  and  cost 

effective solution for

 

domestic hot water 

supply during the warm season.

The 

PK Select CL

 collector is furnished by 

high  efficiency  absorber  coating  of  TiO 

–  Titans oxidation

.  This  special  coating 

is  temperature-  and  wear-proof.  Its 

absorptance rate is 95%, while its thermal 

loss is barely 5%.

2.2. Heat-carrier pipe system

Diagram 2.

Copper  is  irreplaceable  when  it  comes 

to  heat  transfer.  The  liquid  tight  harp

  of 

copper  tubing  ensures  high  efficiency 

and reliability. 

Pipe  harp  with  low 

flow  resistance.  100%  tested  for  liquid

 

tightness.

Summary of Contents for PK 2.0

Page 1: ...TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL model serial number SUNSYSTEM solar collectors FLAT PLATE COLLECTOR series EVACUATED TUBE COLLECTOR VTC series v0 1...

Page 2: ...t transfer plates 6 4 Transportation of the collector 6 5 Delivery of the collector 6 6 Installation 8 6 1 Installation of flat plate collector 9 6 2 Installation of evacuated tube collector VTC 10 6...

Page 3: ...uring installation and operation the country specific requirements and regulations must be observed local construction regulations on installation on building mass of the system to comply with the bui...

Page 4: ...port the heating system only in the manner described in this manual Installation and maintenance must be performed by a technician service shop authorized for such operations 2 DESCRIPTION OF PK TYPE...

Page 5: ...y has the necessary constructive strength to withstand the year round whims of weather not sacrificing on light weight 3 DESCRIPTION OF VTC TYPE EVACUATED TUBE COLLECTOR 3 1 Evacuated tube Absorber co...

Page 6: ...e use of pallet jack fork truck or other hoisting devices is a must Transportation of Flat plate collectors PK Protective plastic corners are fit on each panel collector frame to protect it from rubbi...

Page 7: ...ectors before connecting collectors to system Before installing PK type collectors remove the protective plastic cor ners from collector frames Do not take out or expose the tubes to sunlight during i...

Page 8: ...n be installed in places where the values for wind load Vm mean wind speed does not exceed 150 km h and snow loads Sk weight of snow mass does not exceed 1 25 kN m according to ENV 1991 1 3 and 1991 1...

Page 9: ...Adjust the support angle as needed Place the collector on the support Fix the collector to support using the clamping clips Make sure all connections are properly secured and will not loosen under ha...

Page 10: ...slopes Diagram 14 6 2 1 Flat roof VTC type collector installation Diagram 15 Installation is carried out by at least two people We recommend consulting with a roofing expert Fix the support onto the...

Page 11: ...e the bar rests on the roof tile Install the two side rails F to fixing straps B Use the screws and therefore provided orifices in the rails Diagram 17 Step 3 At the bottom of both side rails F insert...

Page 12: ...box The upper end of the tube with a silver probe like tip as must fit in the manifold nest The lower end of the tube must pass through tube holder D Place the plastic protector on the bottom of tube...

Page 13: ...service shop for such operations Our warranty does not cover dam age from extremely strong acts of nature We recommend that dam age of collectors be included as a clause in your building insurance Co...

Page 14: ...ary in the summer period In this case we recommend that the system be fitted with a device for heat dissipation or to add more users to the hot water circuit in the summer swimming pool or other simil...

Page 15: ...o increase in temperature until the limit of the temperaure relief valve is reached at which point hot water will be dumped from the system If a PTRV is not installed on the collector steam will form...

Page 16: ...ed to operate at a pressure of 500 kPa achieved by use of a pressure limiting reduction value For the reliable operation of system we recommend you check the lever of the pressure and temperature retu...

Page 17: ...d OPERATION MANUAL 7 8 Connection diagrams Diagram 25 Connection of Flat plate collector K to solid fuel boiler WBS combi tank KSC2 and three way valve Must be performed by an autho rized service tech...

Page 18: ...SSPORT INSTALLATION and OPERATION MANUAL TE TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE Diagram 26 Connection of Evacuated tube collector VTC to solid fuel boiler WBS combi tank KSC2 and t...

Page 19: ...19 AL TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL Diagram 27 Connection of Flat plate collector K to solid fuel boiler WBS solar water tank SON buffer tank P and three way valve...

Page 20: ...INSTALLATION and OPERATION MANUAL TE TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL TE Diagram 28 Connection of Flat plate collector K to solid fuel boiler WBS solar water tank SON buffer tank...

Page 21: ...g pressure pump operation hydraulic connections Checkup of heat carrier fluid replacement thereof 9 2 Cleaning of collectors from dust deposits fallen dry leaves and twigs Keeping the collector surfac...

Page 22: ...tion unsuitable or incorrect use Failure to observe the installation use and maintenance instructions set forth in the installation manual of respective product Improper installation or use as well as...

Page 23: ...mediate replacement of the product he has claimed warranty for before receiving the decision as to the claim said request shall be accompanied by a Purchase requisition from the Commercial Department...

Page 24: ...e Mpa 0 6 Inlet Outlet N P R1 2 Inlet Outlet New Line N P Cu 22 Heat carrier flow rate l m2 h 50 Weight kg 33 38 31 33 36 38 Thickness of solar glass mm 4 2 Material of solar glass K Heat tempered pri...

Page 25: ...chnical features of VTC type Evacuated tube collector Diagram 30 Elements of VTC type Evacuated tube collector 1 Manifold 2 Inlet Outlet sleeve 3 Evacuated glass tube 4 Holder and protector of evacuat...

Page 26: ...tant plastic RAL 9005 Heat carrier pipes material type Copper Heat pipe TU 1 Coating of absorber Selective coating Manifold unit box material insulation Anodized aluminum Polyurethane foam 30 mm Effic...

Page 27: ...ntal protection regulation 12 2 Recycling and waste disposal At the end of life cycle of each product its components are due to be disposed of in conformity with regulatory prescriptions According to...

Page 28: ...garia t 359 54 874 555 f 359 54 874 556 e mail ftrade sunsystem bg 129 Vitosha Blvd 1000 Sofia Bulgaria t 359 02 952 24 05 f 359 02 952 67 20 e mail sunsofia sunsystem bg www sunsystem bg ISO 9001 200...

Reviews: