background image

Blood pressure varies constantly and may change due to:

physical trauma

mental anxieties

smoking

----- exercise

eating

drinking caffeinated or alcoholic beverages

Only a qualified physician can determine whether your blood pressure is normal.

Hypertension:

is high blood pressure, and is most common among adults and the
elderly; left unattended, it can cause serious health problems such as a
stroke, heart attack, etc. Therefore, it is important to monitor blood

pressure on a continued and timely basis.

IMPORTANT:

Only a physician is qualified to interpret your blood pressure
measurements, and no device can replace regular medical exami-
nations by your physician. It is recommended that your physician
review your procedure for using this blood pressure monitor. Your
physician should verify blood pressure measurements before
making adjustments to medication.

Summary of Contents for 7656-10

Page 1: ...C HealtkAt Home w Finger Blood Pressure Monitor l Instruction Booklet Read All Instructions Carefully Before Use Save These Instructions...

Page 2: ...e exhaust velocity is 2 5 mmHg per second at the systolic point each time a measurement is taken 6 DO Wait at least 10 minutes between taking measurements 7 DO Pump unit 30 to 60 mmHg above normal sys...

Page 3: ...nit there are no user serviceable parts Return to Service Station for repair 6 DO NOT smoke during or at least 30 minutes prior to taking blood pressure measurements 7 DO NOT drop or otherwise mechani...

Page 4: ...ood pressure level of blood pressure produced as your heart beats Diastolic The lowest point of blood pressure level of blood pressure produced as your heart rests between beats Millimeters of Mercury...

Page 5: ...y left unattended it can cause serious health problems such as a stroke heart attack etc Therefore it is important to monitor blood pressure on a continued and timely basis IMPORTANT Only a physician...

Page 6: ...lso vary during the day and depending on your physical condition and activity level In general readings will be lower when you are calm and rested and higher following physical activity There will be...

Page 7: ...Cuff Size Adjuster Blood Pressure and Pulse Rate Display I Power Button PARTS OF YOUR BLOOD PRESSURE MONITOR...

Page 8: ...cted Mark flashes when power is turned on and there is air re maining in the Finger Cuff Mark flashes at the com pletion of the measurement until exhaust is complete Measurement began but the pressure...

Page 9: ...to turn l r pressure cannot be mea OFF Press again to ON and Measurement Error sured accurately start the measurement again when 0 appears E r r 1 The pulse is very weak or If you have poor circulati...

Page 10: ......

Page 11: ...osition to open the Finger Cuff fully 2 Insert your left index finger fully into the Finger Cuff Use of alternate finger will result in an improper read ing Left finger is preferred but right finger i...

Page 12: ...position may be the most suitable In this case the X will not appear Inaccurate blood pressure readings will result from improper Finger Cuff adjustments 5 Hold the Monitor steadily at heart level wit...

Page 13: ...te and the resulting blood pressure readings will be indicated in the Display Blood pressure readings Systolic on the left Diastolic on the right will be displayed alternately with the pulse PUL readi...

Page 14: ...Consumption 450mW Operating Environment 10 4O C 50 104 F 30 85 RH Storage Environment 20 C 50 C 4 122 F 30 95 RH is greater Pulse 5 of reading Inflation Automatic using an electronic pump Deflation EC...

Page 15: ...AR WARRANTY This product is warranted for one year from the date of purchase against defects in material and workmanship If the product fails to operate during this period return it prepaid to Service...

Page 16: ......

Reviews: