WHY DOES MY BLOOD PRESSURE FLUCTUATE 

THROUGHOUT THE DAY?

1. Individual blood pressure varies naturally throughout the day.

2. Cuff placement and body position can also affect readings, so try to take the measurement  

     under the same conditions. 

3. Certain medications may cause blood pressure to vary.

4. For comparison, wait at least 3 minutes between measurements.

WHY ARE MY BLOOD PRESSURE READINGS AT HOME 

DIFFERENT FROM AT THE HOSPITAL?

1. A variety of factors may cause blood pressure to fluctuate throughout the day, such as emotions, 

exercise, or the weather.

2. The “white coat effect” may also affect blood pressure if you feel nervous or anxious in a  

clinical setting.

3. When taking blood pressure at home, make sure:

• The cuff is placed on the upper arm and positioned correctly.

• The cuff is not too tight or too loose.

• You relax for five minutes before measuring and take 5-6 deep, calming breaths.

WILL THE RESULTS BE THE SAME IF MEASURING ON 

THE RIGHT ARM?

It is ok to measure on either arm, but results may vary. We suggest you measure the same  

arm everytime.

PROBLEM

DISPLAY

CAUSE

SOLUTION

NO

POWER

Display will not 

light up.

Batteries are 

exhausted.

Replace with new 

batteries.

Batteries are inserted 

incorrectly.

Insert the batteries 

correctly.

AC adapter is inserted 

incorrectly.

Insert the AC adapter.

LOW

BATTERIES

Display is dim or 

show  

Batteries are low.

Replace with new 

batteries.

ERROR

MESSAGE

E 1

The cuff is not secure.

Refasten the cuff and 

measure again.

E 2

The cuff is very tight.

Refasten the cuff and 

measure again.

E 3

The pressure of the cuff 

is excessive.

Relax for a moment

and measure again.

E 10 or E 11

The monitor detected 

motion, or a weak pulse 

during measurement

Relax for a moment and 

measure again.

E 20

The measurement process 

does not detect the 

pulse signal.

Loosen clothing on the 

arm and measure again. 

E 21

The treatment of the 

measurement failed.

Relax for a moment and 

measure again.

EExx

A calibration error 

occurred.

Retake the measurement. 

If the problem persists, 

contact our customer 

service department for 

further assistance. Refer 

to the warranty for contact 

information and return 

instructions.

WARNING

MESSAGE

Out

Out of measurement 

range.

Relax for a moment. 

Refasten the cuff and 

measure again. If the 

problem persists, contact 

your physician.

Summary of Contents for TMB-1583-S

Page 1: ...Upper Arm Blood Pressure Monitor with Comfort Inflate Technology Instruction Manual Model TMB 1583 S Item 16985 Manual Version V1 0 Issue Date 2021 07 12...

Page 2: ...od Pressure Monitor is a digital monitor intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging from 8 16 about 22 cm to 42 cm It is intended for indoor adult u...

Page 3: ...end medical treatment without asking a physician for treatment advice If you are taking medication consult your physician to determine the most appropriate time to measure your blood pressure Never c...

Page 4: ...0 kPa 300 mmHg detach the cuff from the arm and press the START STOP button to stop inflation Before use make sure the device functions safely and is in proper working condition DO NOT use the device...

Page 5: ...ee records in memory Current Time Time and date year month day hour minute I I Blood pressure level Indicates the blood pressure level H Hour The hour in the clock mode M Minute The minute in the cloc...

Page 6: ...pose of the batteries in fire Batteries may explode or leak Remove batteries if the device is not likely to be used for some time Worn batteries are harmful to the environment Do not dispose with hous...

Page 7: ...monitor is off press and hold SET to enter the mode for year setting 3When you reach the correct year press SET to confirm the entry 4 Repeat steps 2 and 3 to set the DATE FORMAT then set the MONTH an...

Page 8: ...Wait at least 3 minutes between measurements This allows your blood circulation to recover Take the measurement in a silent room Relax as much as possible and do not move or talk during the measuremen...

Page 9: ...ned to the first 1 record All other records are pushed back one digit e g 2 becomes 3 and so on and the last record 60 is dropped from the list NOTE The current measurement is 01 The corresponding dat...

Page 10: ...SUREMENT Measurements may be inaccurate if taken in the following circumstances Within 1 hour of eating or drinking Immediately after tea coffee or smoking Within 20 minutes of bathing While talking o...

Page 11: ...0 DIA 80 80 84 85 89 90 99 100 109 110 Grade 3 hypertension severe Grade 1 hypertension mild Grade 2 hypertension moderate An irregular heartbeat is detected when a heartbeat rhythm varies while the u...

Page 12: ...he same arm everytime PROBLEM DISPLAY CAUSE SOLUTION NO POWER Display will not light up Batteries are exhausted Replace with new batteries Batteries are inserted incorrectly Insert the batteries corre...

Page 13: ...F 104 F 5 C 40 C within 3 mmHg 0 4 kPa Pulse value 5 Normal working condition A temperature range of 41 F 104 F 5 C 40 C A relative humidity range of 15 to 90 non condensing but not requiring a water...

Page 14: ...ic Compatibility EN 60601 1 2 2015 IEC 60601 1 2 2014 Medical electrical equipment Part 1 2 General requirements for basic safety and essential performance Collateral standard Electromagnetic disturba...

Page 15: ...ctromagnetic emissions Emissions test Compliance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Class A Voltage fluctuations flicker emissions IEC 61000 3...

Page 16: ...430 470 GMRS 460 FRS 460 FM c 5k Hz deviation 1 kHz sine 2 0 3 28 710 704 787 LTE Band 13 17 Pulse modulation b 217 Hz 0 2 0 3 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5...

Page 17: ...pm EST Monday Friday or contact us at info stareliteinc com Our customer service will be happy to assist you 2021 Sunbeam Products Inc All rights reserved Distributed by Star Elite Inc 1175 Place du F...