Page 23
9.0
Operating Instructions
The spa control system has automatic functions that operate upon
startup and normal operation to protect the system. Upon power up, the
readout displays the following information:
1. Control panel displays current software release
(e.g. 3.56), then;
2. Control panel displays “888” and all indicator LEDs are
lit, permitting visual inspection of all display segments
and indicator lights for proper operation.
3. After the initial start-up sequence ends, the actual
water temperature is displayed. If water temperature
at this time is less than the factory default temperature
setting of 100 °F (38 °C) and the spa is set to either of
the standard filtration/heating modes (page 2
8), the heater will turn
on and run until the water temperature rises to the factory setting,
then turn off.
Note: It is common for the heater to turn on after the
spa is first filled because tap water is often very cold.
4. Approximately two minutes after power is applied to the spa, the first
filtration/heating cycle turns on pump 1. In Certa/Chelsee/Hamilton
models, an automatic five minute “blow-out” function also activates
pump 2 for a period of five minutes to flush all lines. Then, after five
minutes, pump 2 turns off and pump 1 continues to operate for the
duration of the cycle.
Note: This function only occurs during the first
filtration/heating cycle each day.
9.1
Setting Water Temperature
The spa’s thermostat provides optimum control of water tem
-
perature. The temperature setpoint (set temperature) can be
adjusted from 65-104 °F (18-40 °C). To raise the set tempera-
ture, press the
WARMER (
)
button. To lower the set temperature,
press the
COOLER (
)
button.
Note: The first press of either button
displays the set temperature.
9.2
Activate Jets Pumps
The
JETS 1
button activates the functions of the main
2-speed jets pump. The first press activates pump 1 in low
speed, the second press activates high speed, and the third
press shuts the pump off. For 2-pump models, the
JETS 2
button controls jets pump 2 which only operates in high speed. When
manually activated, both pumps automatically turn off in 20 minutes.
1.
2.
3.
1
2