background image

Page 8

ELITE SERIES

3.3 

Important Additional CSA Safety Instructions (Canada Only)

When using this electrical equipment, basic safety precautions should 

always be followed, including the following:

1. 

REAd ANd FOLLOW ALL INSTRUCTIONS.

2.  A green colored terminal or a terminal marked G, Gr, Ground, 

Grounding or the 

 symbol* is located inside the supply terminal box 

or compartment. To reduce the risk of electric shock, this terminal must 

be connected to the grounding means provided in the electric supply 

service panel with a continuous copper wire equivalent in size to the 

circuit conductors that supply this equipment (*IEC Publication 417, 

Symbol 5019).

3.  At least two lugs marked “Bonding Lugs” are provided on the external 

surface or on the inside of the supply terminal box/compartment. To 

reduce the risk of electric shock, connect the local common bonding 

grid in the area of the spa to these terminals with an insulated or bare 

copper conductor not smaller than No. 6 AWG (10 mm²).

4.  All field-installed metal components such as rails, ladders, drains

   or other similar hardware within 10 feet (3m) of the spa shall be 

bonded to the equipment grounding buss with copper conductors not 

smaller than No. 6 AWG (10 mm²).

5. 

SAvE THESE INSTRUCTIONS.

3.4 

General Electrical Safety Instructions

Your new Sundance

®

 Spa is equipped with a "state-of-the-art" 

equipment system. It contains the most advanced safety and self-

protective equipment in the industry. Nonetheless, this spa must be 

installed properly to ensure dependable usage. Please contact your 

local Sundance dealer or local building department should you have any 

questions regarding your installation.

Proper grounding is extremely important. Sundance spas are equipped 

with a current collector system. A pressure wire connector is provided 

on the surface of the control box, located outside the equipment door 

(Figure B, page 

1

4

) to permit connection of a bonding wire between 

this point and any ground metal equipment, metal water pipe or conduit 

within 5 feet (1.5m) of the spa, or copper clad grounding rod buried 

within 5 feet (1.5m) of the spa. Bonding wire must be at least No. 8 AWG 

(8.4 mm²) solid copper wire. This is a most important safety assurance 

feature. 

Before installing your spa, check with your local building department to 

ensure installation conforms to local building codes.

Summary of Contents for CONSTANCE

Page 1: ...o w n e r s m a n u a l 6530 512X Rev A EL I T E Constance Victoria S E R I E S...

Page 2: ...pm Calcium Hardness 150 250 ppm To decrease RISK OF Infection or Disease Always maintain your spa filter as outlined below to ensure healthy spa water Refer to pages 35 36 for additional information R...

Page 3: ...a Features 22 8 3 Victoria Air Controls Diagram 23 8 4 Victoria Massage Waterfall Selector Diagram 24 8 5 Constance Spa Features 25 8 6 Constance Air Controls Diagram 26 8 7 Constance Massage Waterfal...

Page 4: ...Panel displays SN2 45 13 5 Panel displays FL1 or FL2 45 13 6 Panel displays COL 45 13 7 Panel displays ICE 45 13 8 Panel displays 46 14 0 Troubleshooting Procedures 46 14 1 None of the Components Oper...

Page 5: ...ined herein 2 0 FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea...

Page 6: ...lead to drowning or severe injury Never use the spa unless all suction guards filter filter lid or skimmer assembly are installed to prevent body and or hair entrapment Never operate or use the spa i...

Page 7: ...r GFCI as required by NEC Article 680 42 4 WARNING Risk of Severe Injury or Death Extreme caution must be exercised to prevent diving or jumping into the spa or slipping and falling which could result...

Page 8: ...ng spa use may lead to unconsciousness with the possibility of drowning 7 WARNING Risk of Severe Injury or Death Prolonged immersion in a spa may be injurious to your health Observe a reasonable time...

Page 9: ...in a commercial or public application The spa buyer shall determine whether there are any code restrictions on the use or installation of this spa since local code requirements vary from one locality...

Page 10: ...has been reported in persons who when submerge themselves underwater allowing hair to come close and or within the reach of the suction fittings suction covers or skimmer assembly Keep hair away from...

Page 11: ...skimmer assembly Never allow children to play or get near the suction fittings suction covers filter filter lid or skimmer assembly 3 2 Hyperthermia Prolonged immersion in hot water may induce hypert...

Page 12: ...r hardware within 10 feet 3m of the spa shall be bonded to the equipment grounding buss with copper conductors not smaller than No 6 AWG 10 mm 5 SAVE THESE INSTRUCTIONS 3 4 General Electrical Safety I...

Page 13: ...s to provide drainage away from it Placing the spa in a depression without provisions for proper drainage could allow rain overflow and other casual water to flood the equipment and create a wet condi...

Page 14: ...borne illness e g an infection bacteria or virus and or respiratory ailments that could be present in the air or water Consult a licensed architect or building contractor to determine your specific ne...

Page 15: ...ded that you plan your indoor installation to provide full access to the entire spa WARRANTY Damage caused by not following these guidelines or any improper installation not in accordance with local c...

Page 16: ...In 60A configuration the heater will operate while both jets pumps are running in high speed Note pump 2 runs only in high speed 5 2 Export 50 Hz Power Options Export 2 Pump Models 50 Hz 230V 20A 230...

Page 17: ...oper connections Do not use aluminum wire When using wire larger than 6 10 mm add a junction box near the spa and reduce to short lengths of 8 8 4 mm wire to connect to the spa 4 The electrical supply...

Page 18: ...e s 3 2 Speed Pump 1 4 Heater 5 Spa Drain Valve 6 Pump Drain Plugs 7 1 Speed Pump 2 8 Ozone injector 9 Optional CD Ozonator Injector Connection Purchased separately on North American models standard e...

Page 19: ...INIMIZE ACRYLIC DAMAGE Never fill with water from a water softener If your water is extremely hard it is preferable to fill half way with hard water and the rest of the way with softened water Water t...

Page 20: ...s recommended by your Sundance dealer See Section titled Water Quality Maintenance page 42 for general guidance WARNING Risk of poisoning or death Never leave chemicals opened and accessible to anyone...

Page 21: ...to low speed and jets pump 2 must be turned off to operate the heater For Export 50 Hz 2 pump spas powered by a 20 amp service jet pump 1 must be set to low speed and jets pump 2 must be turned off to...

Page 22: ...ithin your hot tub burn or irritate your skin create a rash and void the manufacturer warranty for your spa Water Fill Capacity by Model Average Sodium Model Fill Volume dichlor Constance 375 Gal 1 41...

Page 23: ...est headrest DO NOT OVERFILL CAUTION TO DECREASE BUILD UP ON COMPONENTS AND MINIMIZE ACRYLIC DAMAGE Never fill with water from a water softener If your water is extremely hard it is preferable to fill...

Page 24: ...er reading between 3 0 4 0 ppm chlorine or 2 0 4 0 ppm bromine then allow the spa to set undisturbed for 8 hours Retest water after 8 hours to determine if sanitizer levels are stable If sanitizer lev...

Page 25: ...pump 2 off G Light On Off Button Turns waterfall footwell and air control lights on in unison Press once for high intensity press a second time for medium intensity press a third time for low intensi...

Page 26: ...14 Accu Pressure Jets 6 15 Fluidix ST Jets 7 16 Optional Audio System Speakers 6 each 17 Waterfall w LED Light 18 Optional Stereo Receiver with MP3 player connector page 50 19 Top Railing 1 Control P...

Page 27: ...3 ELITE SERIES 8 3 Victoria Air Controls Diagram Air Control Operation Rotate Air Controls 1 3 to add air to designated jet groups Spa features subject to change without notice 1 2 2 2 1 3 3 3 1 1 1 2...

Page 28: ...d jet groups Spa features subject to change without notice Massage Selectors 1 Massage Selector 1 controls pump 1 Jets 2 These jets are always on when the jets pump 2 is running Waterfall 3 Waterfall...

Page 29: ...lter Lid Filter Cartridge 3 Air Controls w LED Light 4 4 Pillows 4 5 Massage Selector 6 Gravity Drain Ozone Return Heater Return Fitting 7 Spa Light 8 Suction Fittings 4 9 Nex Jets 6 10 Fluidix Reflex...

Page 30: ...ITE SERIES 8 6 Constance Air Controls Diagram Air Control Operation Rotate Air Controls 1 4 to add air to designated jet groups Spa features subject to change without notice 1 2 2 2 2 1 1 1 1 1 3 3 3...

Page 31: ...or 1 to divert water between desig nated jet groups Spa features subject to change without notice Massage Selectors 1 Massage Selector 1 controls pump 1 Jets 2 These jets are always on when the jets p...

Page 32: ...n also activates pump 2 for a period of five minutes to flush all lines Then after five minutes pump 2 turns off and pump 1 continues to operate for the duration of the cycle Note This function only o...

Page 33: ...tween positions due to the large amounts of water flowing through it For optimum filtration benefits leave the valve in position A when spa is covered Select position B or C for maximum jet performanc...

Page 34: ...ess Again Press Again High Speed Color Blend Mode Low Speed Color Blend Mode BLUE X4 VIOLET X5 RED X6 AMBER X7 GREEN X8 AQUA X9 WHITE X10 NEAR 9 6 Exterior Lights Your spa comes standard with eight ex...

Page 35: ...l create an oscillating flow The included tool shown allows you to position the jet nozzle angle to your liking This tool can also be used to aid in the opening or closing of the nozzle on Fluidix Ref...

Page 36: ...10 1 and 10 2 below for additional information 10 1 Standard Filtration Heating Modes F0 F3 Standard filtration heating modes are typically selected by customers in cold climates where heat up times a...

Page 37: ...eating per day one 30 minute cycle every 12 hours F5 1 5 hours of filtration heating per day one 30 minute cycle every 8 hours F6 2 hours of filtration heating per day one 30 minute cycle every 6 hour...

Page 38: ...Page 34 ELITE SERIES...

Page 39: ...covers or pump s be sure that the flow rates are compatible and are in compliance with the VGB Safety Act page 2 Never replace a suction fitting or suction cover with one rated less than the flow rate...

Page 40: ...filter onto clean stage 1 filter 2 Insert retainer into stage 2 filter and rotate clockwise to assembly DO NOT OVERTIGHTEN RETAINER FINGER TIGHT ONLY G 1 Install filter assembly then tighten filter n...

Page 41: ...out every 3 months or as needed DO NOT reuse this cartridge Attempts to reuse this cartridge will reintroduce debris back into your spa Replacement cartridges may be purchased from your Sundance deale...

Page 42: ...Spa Fill Up Procedure page 15 for recommended filling instructions 11 3 Pillow Care Remove and clean the headrest pillows as needed with soapy water using a cloth or soft bristle brush Always remove t...

Page 43: ...er Do not use soap on the underside of the cover 3 Please check with your Sundance Spa Dealer for recommended cover care and conditioning products Condition using non petroleum based conditioners to k...

Page 44: ...sure all locks have been released to avoid lock breakage and or cover strap damage 11 6 Maintaining The Synthetic Cabinet Your new spa s synthetic cabinet requires little or no maintenance of any kind...

Page 45: ...vacuum or other means to keep this from flooding the equipment compartment Replace the drain plugs 6 Loosen the hose clamp on the circulation pump intake behind the control box Figure A page 14 and p...

Page 46: ...tizing and maintaining your hot tub WARNING Failure to maintain water quality WILL Increase risk of contracting a waterborne illness e g an infection bacteria or virus and or respiratory ailments Dama...

Page 47: ...ave your hot tub unattended for any reason while the cover is open and accessible especially to small children and animals CAUTION Risk of PERSONAL injury OR SPA DAMAGE Never add chlorine tablets tric...

Page 48: ...is directly affected by the ambient temperature An excessively hot ambient temperature may prevent the spa from cooling down because it s fully insulated construction is designed to retain heat and t...

Page 49: ...3 Purge air lock from circulation pump intake by removing the filter cartridge Hold your garden hose over the filter wall fitting with grate using a rag as a seal around hose end then ask a helper to...

Page 50: ...ust be replaced by authorized service personnel 14 1 None of the Components Operate e g Pump Light Check the following 1 Is there power to the spa 2 Is the household circuit breaker tripped 3 Call you...

Page 51: ...ings to see if your spa is in economy filtration heating mode pages 32 33 Should checking the above steps fail to correct the problem please call your dealer so that they may arrange service We build...

Page 52: ...r 50A Logic JP1 7 8 ON C Temperature Display JP1 7 8 OFF F Temperature Display J1 J2 J3 F1 30A 250V SC 30 Pump 1 Transformer 240 VAC J4 F1 JP1 4 2 3 1 6 5 8 7 HI LO C Control Panel Circ Pump J20 K1 K2...

Page 53: ...BRN 2 1 Flow switch Hi limit freeze sensor Temperature sensor J1 J2 J3 F1 20A 250V SC 20 Pump 1 Pump 2 Transformer 230 VAC J4 F1 JP1 4 2 3 1 6 5 8 7 HI HI LO C Control Panel Circ Pump J20 K1 K2 K3 K4...

Page 54: ...D into slot DO NOT FORCE Make sure to close the front panel to prevent damage to the unit Eject Button Not Illustrated After releasing the front panel press the Eject button located to the left of CD...

Page 55: ...0 10 Dimmer The dimmer feature of the display is set to DIMMER High by default Use the Volume Up or Down buttons to adjust the Dimmer level between High or Low Distant Local Distant is the default se...

Page 56: ...ofer Level User has 5 seconds to use the Volume Up or Down button to adjust the Sub woofer lever from 00 to 12 Note The Sub woofer level control is only applicable if the unit is equipped with the opt...

Page 57: ...lume Up or Down button to adjust the desired Middle level range from 6 to 6 MID CFQ Middle Cent er Frequency User has 5 seconds to use the Volume Up or Down button to adjust the desired Middle Range C...

Page 58: ...s from R12 full right to L12 full left C00 represents an equal balance between the right and left speakers FADER User has 5 seconds to use Volume Up or Down button to adjust the Fader between the fron...

Page 59: ...ars in the display When no stereo signal is available the unit will automatically revert to mono operation and no icon will be displayed 15 Preset 1 Pause Play Button In Tuner mode any station can be...

Page 60: ...nds after the desired station is selected To recall the station preset simply press and release this button In CD mode this button will browse the folders on CD R and CD RW discs 21 Tuning Up Button P...

Page 61: ...1 kHz 48kHz for MP3 Bit rates 32 320 Kbps MP3 decoding format MPEG 1 2 2 5 Audio Layer 3 Folder names and file names can be displayed with up to 11 characters The characters A Z 0 9 can be displayed...

Page 62: ...Signal to Noise 80 dB Stereo Separation 45 dB Capture Ratio 2 0 dB AM tuning Range 530 1 710 kHz Usable Sensitivity IEC Standard 22 5 27 0 v dBf General Power DC 11 5 14 4V Pre Output Voltage 5V Curre...

Page 63: ...elow An outline of a media with MP3 WMA is shown below Subfolders are shown as folders in the folder currently selected The equipment assigns folder numbers The user cannot assign folder numbers It is...

Page 64: ...at play the current file and keep on repeat playing the current file until the repeat play is disabled To disable current file repeat play press M3 button less than 3 seconds 3 File Folder Random play...

Page 65: ...been made consult your nearest service dealer Symptom Cause Solution No power The fuse is blown Replace the fuse Disc cannot be loaded or ejected Presence of CD disc inside the player Remove the disc...

Page 66: ...vides control over some of the radio and CD playback functions A External iPod MP3 Playback The supplied remote control provides no control over external iPod MP3 player operation of any kind with the...

Page 67: ...o move forward tracks or press and hold to do a fast forward In radio mode Seeks up for stations BAND SEARCH Band Search Button In radio mode Switches bands between FM1 FM2 FM3 AM1 and AM2 AUDIO SEL A...

Page 68: ...d start playback prior to plugging in iPod MP3 Player 2 Press the Mode button on stereo receiver or the mode button on the remote until the display reads AUX C C Operating iPod MP3 Player All playback...

Page 69: ...to pry the door upward Figure C 4 Replace battery using CR2025 or equivalent Figure D 5 Reinstall the battery cover using the coin to close Figure E Note Remote unit is water resistant not waterproof...

Page 70: ...Page 66 ELITE SERIES...

Page 71: ...Page 67 ELITE SERIES...

Page 72: ...Page 68 ELITE SERIES...