6.0 Electrical Wiring Instructions
Important Notice:
The electrical supply to this product
must be installed by a qualified, licensed electrician to
comply with all regulations and standards specified by the
electrical authority in your state or country.
1. A 240 VAC powered spa must be permanently connected (hard-
wired) to the power supply. No plug-in connections or extension
cords are to be used in conjunction with the operation of this spa.
Supplying power to the spa which is not in accordance with these
instructions will void both the independent listing and the
manufacturer’s warranty.
2. The power supplied to this spa must be a dedicated circuit with
no other appliances or lights sharing the power provided by the
circuit.
3. To gain access to the spa’s power terminal strip, remove the
spa’s cabinet panel on the light side of the spa. Then remove the
faceplate from the load box. Refer to sections 13.1-13.3 (page
28-29) for your specific spas load box location.
4. Locate the hole in the cabinet (above the pan) and feed the wires
through (Solo spa only).
5. Connect the wires to main terminal block TB1. Refer to figures
G-I for your specific spas terminal block configuration.
Tighten
securely!
All wires must be hooked up or damage could result.
6. The electrical supply for this product must include an electrical
installation and circuit breaker that complies with local electrical
regulations.
7. A suitably rated GFCI or RCD must be installed at the power
supply in the house electrical box.
8. Reinstall the face plate and the cabinet panel.
GRN
WHT
WHT
BLK
BLK
BLK
RED
1
2
3
fig. G
TB1
to Circuit
Board
Po
w
er In
GRN
WHT
WHT
BLK
BLK
BLK
RED
RED
1
2
3
All US/Canada Convertible Models:
120/240 VAC, 4-Wire Connection (60 Hz)
fig. H
TB1
to Circuit
Board
Po
w
er In
All US/Canada Convertible Models:
120 VAC, 3-Wire Connection (60 Hz)
8