be used.  After cleaning, thoroughly rinse and dry.  You may want to leave the doors open 
allowing the compartments to ventilate for 20-30 minutes to get rid of residual odors. 

 
Positioning 

 

The area in which the appliance is to be installed should be relatively cool, dry, and suitably 
ventilated. The area should be protected against any beating rain and free of abundant dust.  To 
ensure proper function, the appliance must be placed horizontally on a flat, firm, and stable 
surface resting level on all four supports. Use wood or metal shims to level the appliance if 
necessary. Do not place the appliance close to heat sources (heater, stove, boiler, chimney, etc.), 
and avoid exposure to direct sunlight.  

A minimum spacing of 3 inches (7.5cm) behind the 

refrigerator is highly recommended. 

This will provide sufficient airflow around the condenser 

resulting in more efficient operation and longer appliance lifetime. Always keep the air vent 
openings of the compressor housing cover free from dust and obstructions.  

 
ELECTRICAL CONNECTION (12 or 24VDC Only)  

The refrigerator will automatically turn on when 12 OR 24VDC power is connected.  There is no 
separate on/off switch and no requirement to select the operating voltage.  

Do not connect 

power until you have completed the installation instructions. 

Polarity is important in wiring this DC appliance. The red (or black wire with a red stripe) is the 
positive wire.  The black wire is negative.  The unit is not damaged by reverse polarity, but will 
not run.  Some components in the unit may be damaged if more than 31VDC is applied  

 
Fuse 

 

The  user  must  provide  a  fuse  to  protect  the  wiring.  A 
standard  automobile  fuse  is  recommended  and  the  fuse 
should  be  wired  to  the  positive  (“+”)  side  of  the  system 
close to the positive battery terminal.  
 
If  a  longer  connection  cable  is  necessary,  the  wire  gauge  must  be  equal  to  or  greater  than  the 
wire sizes recommended on the following table. Be careful that the input voltage at the appliance 
does not drop below the cut-out voltage of the compressor.  Inadequate wiring or poorly made 
wire connections are a very common reason the appliance will not run or not run consistently. 
 

Cable Size 

 

12V Cable Length 

 

24V Cable Length 

 

mm

2

  

AWG  

m  

ft.  

m  

ft.  

2.5  

12  

10  

33  

20  

66  

 

Operating 

Voltage 

 

Fuse 

 

12V  

15A  

24V  

7.5A  