4. Switch off position for stacked curtain
The motor can optionally be fixed on the right or left side of the curtain track rail.
The motor has not yet been mounted!
1. Move traverse joint manually to the required stack
position, sticker plus 1 cm
(illustr. 3).
2. Take care that the motor bar is in the rail gear.
3. Turn motor into the bajonett coupling, until the covers
of the adjusting switches show towards the room.
At the same time the traverse joint moves to a
position directly above the sticker.
While turning in push both bottons at the same time.
4. Now the switch off postion for stacked drapery is already
fixed. Pressing motor key or
traversing is not necessary!
5. Switch-off position for closed curtain
Start motor. The motor does only respond to the control switch “shut curtain” and traverses abt. 500 mm. Put
control switch in null-position. The moving direction of the traverse joint is according to the arrow on the
control switch. If not, change black and brown connection cable
at control switch. Remove cover cap for motor keys
(ill. 4)
. Keep
on pressing upper motor key and press control switch for
moving direction “shut curtain”. Move traverse joint to switch
off position “shut curtain”
(illustr. 5)
. You can shuttle as long as
the exact position has been reached.
Advice: alternatively you can also engage the switch setting
“shut curtain” and move the traverse joint towards switch off
position “shut curtain” by tapping the upper motor key.
Important: As soon as you release the motor key, a switch-off
position is memorized. To modify this memorized position, turn
control switch to null-position, re-press the upper motor key and
then engage control switch “shut curtain” until the requested
switch-off postion is reached. The same proceeding can be
applied in order to modify a memorized stack position, in this
case just re-press the lower motor key.
The motor keys can also be kept pressed by means of the cover
cap
(ill. 6)
. So the operater may, especially in case of long rails,
move away from the motor in order to better adjust switch-off
position “shut curtain”. Same proceeding is applicable for
switch-off position “stacked curtain”. The switch-off positions
can also be adjusted manually with the help of the cover cap:
Press control switch “shut curtain”. Wait until the motor stops.
Put control switch into null-position.
Engage upper motor key by means of cover cap. Move traverse
joint manually to desired switch-off position.
Remove cover cap.
Switch-off position is adjusted and memorized. Same proceeding
is applicable for a simple modification of switch-off position
“stacked curtain” is possible.
1. Technical data
Nominal voltage
230 V
Nominal power
50 W
Nominal current
0,23 A
Frequency
50 Hz
Operating mode
S3 50%
Sense of rotation
right/left
Nominal speed
750 rpm
Protection
only for dry rooms
Certificate
CE
Connection
4 x 0,75 mm
2
, 1 m long
Dimensions
width 60 x 40 x height 192 mm
Speed 290
mm/s
Rail length
up to 7000 mm
Drapery weight
15 kg
Switch off
yes, push button
Radio control
yes
Groups
yes
2. Electrical connection
The motor is being delivered ready for connection and has
to be wired color-coded at the free end of the motor wire.
In certain cases it might be necessary to wire the supply
directly in the motor.
For this open the lower cover
(illustr. 1)
carefully, guide the
cable through the cable grommet and wire according to
illustr. 2. The connection board can be lift up abt. 20 mm
and has to be pressed down cautiously after wiring. Close
cover again. Use for operation only locked push button
switches like venetian blind switches or comfortable swit-
ches with visual null-position. Wiring diagram see overleaf.
3. Switch off positions
On delivery the switch off position “open curtain” (stack
position) as well as traverse path of abt.
500 mm are preset.
Do not activate the motor until star-
ting up the curtain track!
illustr. 3
illustr. 2
illustr. 1
illustr. 5
direction of rotation “open curtain” (stack
position) anti-clockwise
yellow/green brown black grey
illustr. 4