4. Switch off position for stacked curtain

The motor can optionally be fixed on the right or left side of the curtain track rail. 
The motor has not yet been mounted!
1. Move traverse joint manually to the required stack 

position, sticker plus 1 cm

(illustr. 3).

2. Take care that the motor bar is in the rail gear. 
3. Turn motor into the bajonett coupling, until the covers 

of the adjusting switches show towards the room. 
At the same time the traverse joint moves to a
position directly above the sticker. 
While turning in push both bottons at the same time.

4. Now the switch off postion for stacked drapery is already
fixed. Pressing motor key or 

traversing is not necessary!

5. Switch-off position for closed curtain 

Start motor. The motor does only respond to the control switch “shut curtain” and traverses abt. 500 mm. Put
control switch in null-position. The moving direction of the traverse joint is according to the arrow on the
control switch. If not, change black and brown connection cable
at control switch. Remove cover cap for motor keys 

(ill. 4)

. Keep

on pressing upper motor key and press control switch for
moving direction “shut curtain”. Move traverse joint to switch
off position “shut curtain” 

(illustr. 5)

. You can shuttle as long as

the exact position has been reached. 
Advice: alternatively you can also engage the switch setting
“shut curtain” and move the traverse joint towards switch off
position “shut curtain” by tapping the upper motor key.
Important: As soon as you release the motor key, a switch-off
position is memorized. To modify this memorized position, turn
control switch to null-position, re-press the upper motor key and
then engage control switch “shut curtain” until the requested
switch-off postion is reached. The same proceeding can be
applied in order to modify a memorized stack position, in this
case just re-press the lower motor key. 
The motor keys can also be kept pressed by means of the cover
cap

(ill. 6)

. So the operater may, especially in case of long rails,

move away from the motor in order to better adjust switch-off
position “shut curtain”. Same proceeding is applicable for
switch-off position “stacked curtain”. The switch-off positions
can also be adjusted manually with the help of the cover cap:
Press control switch “shut curtain”. Wait until the motor stops.
Put control switch into null-position.
Engage upper motor key by means of cover cap. Move traverse
joint manually to desired switch-off position.
Remove cover cap.
Switch-off position is adjusted and memorized. Same proceeding
is applicable for a simple modification of switch-off position
“stacked curtain” is possible.

1. Technical data

Nominal voltage

230 V

Nominal power

50 W

Nominal current

0,23 A

Frequency

50 Hz

Operating mode 

S3  50%

Sense of rotation

right/left

Nominal speed

750 rpm

Protection

only for dry rooms

Certificate

CE

Connection

4 x 0,75 mm

2

, 1 m long

Dimensions

width 60 x 40 x height 192 mm

Speed 290 

mm/s

Rail length

up to 7000 mm

Drapery weight

15 kg

Switch off

yes, push button

Radio control

yes

Groups

yes

2. Electrical connection

The motor is being delivered ready for connection and has
to be wired color-coded at the free end of the motor wire.
In certain cases it might be necessary to wire the supply
directly in the motor. 
For this open the lower cover 

(illustr. 1)

carefully, guide the

cable through the cable grommet and wire according to
illustr. 2. The connection board can be lift up abt. 20 mm
and has to be pressed down cautiously after wiring. Close
cover again. Use for operation only locked push button
switches like venetian blind switches or comfortable swit-
ches with visual null-position. Wiring diagram see overleaf. 

3. Switch off positions

On delivery the switch off position “open curtain” (stack
position) as well as traverse path of abt. 
500 mm are preset.

Do not activate the motor until star-

ting up the curtain track!

illustr. 3

illustr. 2

illustr. 1

illustr. 5

direction of rotation “open curtain” (stack
position) anti-clockwise

yellow/green brown black grey

illustr. 4

illustr. 6