•  Connect the hose to the control valve inlet. Fig 3.

•  The mask is now being supplied with air and you can put it on.

•  Use the regulator knob to set the air flow rate to suit your 

current work intensity. Fig. 2.

  In the fully closed position (turn the knob anti-clockwise), the 

flow is about 5.3 CFM (150 l/min), and in the fully open position 

(turn the knob clockwise), it is about 12 CFM (340 l/min).

•  The breathing hose retaining clip which is supplied can be 

used to advantage for securing the breathing hose to your 

body. Fig. 1:11

2.5  Taking the equipment off

Leave the polluted work area before taking the equipment off.

•  Remove the mask

Releasing the air supply hoses:

CEJN connectors 

Push the coupling towards the nipple, at the same time pulling 

the locking ring back. Fig. 4.

Schrader and Hansen connectors

Twist the locking ring on the coupling.

Releasing the breathing hose:

Push the coupling towards the nipple, at the same time pulling 

the locking ring back. Fig. 4.

After every period of use, check that no defects have occurred, 

and clean the equipment. See 4.1.

2.6  Cautions / limitations

A

 -  Not for use in atmospheres containing less than 19.5 

percent oxygen. 

B

 -  Not for use in atmospheres immediately dangerous to life 

or health.

C

 -  Do not exceed maximum use concentrations established 

by regulatory standards.

-  Air-line respirators can be used only when the respirators 

are supplied with respirable air meeting the requirements 

of CGA G-7.1 Grade D or higher quality.

E

 -  Use only the pressure ranges and hose lengths specified 

in the User’s Instructions.

J

 -  Failure to properly use and maintain this product could 

result in injury or death.

M

 -  All approved respirators shall be selected, fitted, used, and 

maintained in accordance with MSHA, OSHA and other 

applicable regulations.

N

 -  Never substitute, modify, add, or omit parts. Use only 

exact replacement parts in configuration as specified by 

the manufacturer.

-  Refer to User’s Instructions, and/or maintenance manuals 

for information on use and maintenance of these respira-

tors.

S

 -  Special or critical User’s Instructions and/or specific 

use limitations apply. Refer to User’s Instructions before 

donning.

Do not use 

−  If the ambient air does not have a normal oxygen content.

−  If the pollutants are unknown.

−  With oxygen or oxygen-enriched air.

−  If you can smell or taste the pollutants.

−  If you finds it difficult to breath.

− If you experience dizziness, nausea or other types of 

discomfort.

−  If the warning whistle sounds, indicating that the air supply 

is lower than recommended.

−  If the functional check does not produce satisfactory results. 

See 2.3. 

Limitations

−  A person working in an explosive or flammable environment 

must follow any local regulations that may be in force for 

such conditions.

−  At very high work intensity, a partial vacuum may occur in 

the equipment during the inhalation phase, which may cause 

ambient air to be drawn in.

−  The air supply system should be equipped with an appro-

priately rated and adjusted pressure relief safety valve.

−  The equipment is approved only together with Sundström 

compressed air supply hoses.

3.  Technical specification / S – Special 

     or Critical User’s Instructions

Air flow rate

5.3 CFM (150 l/min) to 12 CFM (340 l/min) measured in the 

mask.

Manufacturer’s minimum design flow: 5.3 CFM (150 l/min).

Compressed air supply hoses and regulator 

The hoses and regulator are approved with three alternative 

connectors 

−  CEJN 10 342 series

−  Schrader Twist lock series 

−  Hansen 2RL series

The following hoses have been approved together with SR 307 

compressed air attachment:

Model number SR 358

0.374/0.590 inch (9.5/15 mm) plastic hose made of PVC-

reinforced polyester. 

Length 16.4 feet, 32.9 feet, 49.3 feet, 65.8 feet, 82.2 feet 

and 98.7 feet 

(5 m, 10 m, 15 m, 20 m, 25 m and 30 m).

Model number SR 359

0.374/0.709 inch (9.5/18 m) rubber hose made of EPDM/

polyester. Antistatic and heat resistant.

Length 16.4 feet, 32.9 feet, 49.3 feet, 65.8 feet, 82.2 feet 

and 98.7 feet 

(5 m, 10 m, 15 m, 20 m, 25 m and 30 m).

N.B. The maximum length is 98.7 feet (30 m). 

One length of hose must not be connected to another in 

order to lengthen the hose.

Materials

Plastic parts are marked with the material code and recycling 

symbol.

Shelf life

10 years from the date of manufacture. 

Sizes

Half mask SR 100 Small/Medium

Half mask SR 100 Medium/Large

Half mask SR 90-2 Small/Medium

Half mask SR 90-2 Medium/Large

Full face mask SR 200 one size

Temperature range storage

4 ºF - 104 ºF (-20 ºC to +40 ºC) and a relative humidity  

below 90%.

Summary of Contents for SR307

Page 1: ...Air Respirator User s Instruction Manuel de l utilisation Instrucciones de uso Sundstrom Safety Inc 143 Maple St Warwick RI 02888 Office 1 401 434 7300 Toll Free 1 877 SUNDSTROM Fax 1 401 434 8300 inf...

Page 2: ...2 Please read and save these instructions 3 Illustrations 12 Pri re de lire et de conserver 6 Figures 12 Lea y conserve estas instrucciones por favor 9 Illustraciones 12 Espa ol Fran ais English...

Page 3: ...ose to a compressed air attachment and then into the mask 1 3 Breathable air Breathable air shall conform to the requirements of CGA G 7 1 Grade D or higher quality 2 Use 2 1 Unpacking Check that the...

Page 4: ...efore donning Do not use If the ambient air does not have a normal oxygen content If the pollutants are unknown With oxygen or oxygen enriched air If you can smell or taste the pollutants If you finds...

Page 5: ...tr m parts Don t modify the equip ment The use of pirate parts or any modifications made to the equipment may reduce the protective effect and compromise the approvals granted to the equipment 4 4 1 R...

Page 6: ...glage l air est amen par l interm diaire d un tuyau respiratoire dans un bo tier de raccordement puis dans le masque Le robinet de r glage est quip d un sifflet avertisseur qui se d clenche lorsque l...

Page 7: ...des dommages corporels ou m me une issue fatale M Tous les quipements respiratoires agr s doivent tre choisis mont s utilis s et entretenus en conformit avec les r glementations MSHA OSHA ou autres n...

Page 8: ...inimales en ce qui concerne la maintenance syst matique pour garantir l utilisateur un quipement toujours en tat de servir Avant Apr s Tous les utilisation utilisation deux ans Contr le visuel Contr l...

Page 9: ...quisitos de CGA G 7 1 Grado D o ser de calidad superior 2 Uso 2 1 Desembalaje Controlar que el equipo est completo seg n la lista de contenido y que no haya sufrido da os durante el transporte 2 2 Lis...

Page 10: ...e repuesto exactas en la configuraci n tal como lo especifica el fabricante O Ver las instrucciones de uso y o manuales de manten imiento para informaci n sobre el manejo y mantenimiento de estos resp...

Page 11: ...l esquema de abajo muestra los requisitos m nimos de limpieza peri dica para que el usuario tenga la seguridad de que el equipo est siempre en condiciones de uso Antes Despu s Itervalo de del uso del...

Page 12: ...12 1 9 2 1 11 8 7 6 4 3 5 10...

Page 13: ...13 2 3 6 5 4...

Page 14: ...Notes...

Page 15: ...Notes...

Page 16: ...L37 1421 Rev 07 20160808...

Reviews: