© 2015 SunEdison
6
F-SERIES and R-SERIES
72-Cell Installation Guide
CASE 3
A
LOAD
PARAMETERS
CASE 1
Maximum
Rear Load:
2400 Pa
(50 psf)
Maximum
Front Load:
5400 Pa
(113 psf)
Mounting Color Code: Mounting Hole Location Module Rail Fixed Clamp Mount Clamp Mount
Range
A – 394 mm
B – 248 mm
C – 444 mm
Fixed Clamp Mount location:
Clamp mount allowable range:
A
Clamp Mount
Locations:
Fixed clamp
location for
5400 Pa
front load
Clamp Mount Locations:
Clamp mount allowable range
Case 3, option 1
C
FRONT VIEW
BACK VIEW
CASE 2
DETAILS
Maximum
Rear Load:
2400 Pa
(50 psf)
Maximum
Front Load:
5400 Pa
(113 psf)
Maximum
Rear Load:
2400 Pa
(50 psf)
Maximum
Front Load:
2400 Pa
(50 psf)
CASE 1:
Structural rails
running perpendicular to
the length of the module
should be fixed via bolts at
the mounting holes between
each long side frame, or
Clamps can be mounted
at the Fixed Clamp Mount
location as shown in the
color code key. See 7.3 for
minimum clamp dimensions.
CASE 2:
Structural rails
running parallel to the
length of the module should
be fixed via bolts at the
mounting holes on each
long side frame, or Clamps
can be mounted anywhere
within the Clamp Mount
Range as shown in the color
code key.
CASE 3:
Structural rails
running perpendicular to the
length of the module should
be fixed via bolts at the
mounting holes between each
long side frame, or Clamps
can be mounted anywhere
within the Clamp Mount
Range as shown in the color
code key.
MODULE
ILLUSTRATION
Bolt Mount
Locations
C
BACK VIEW
FRONT VIEW
Bolt Mount
Locations
Clamp Mount
Locations:
Clamp mount
allowable
range
B
C
B
C
BACK VIEW
BACK VIEW
OR
Case 3, option
2
FIGURE 1(a): MOUNTING CONFIGURATIONS