background image

6

Rev. 02/22/02

TROUBLESHOOTING

One side of nozzle wing
is clogged.

PROBLEM

SPRAY PATTERN/
CONDITION

A.) Loose air nozzle.

B.) Material around outside of 

air nozzle has dried.

A.) Atomization air pressure is set 

too high.

B.) Trying to spray a thin material 

in too wide a pattern.

Spitting

SOLUTION

A.) Reduce air pressure.

B.) Increase material control by turning fluid 

control screw to left, while reducing spray 
width by turning spray width adjustment 
screw to right.

Soak nozzle in solvent to loosen clog, then blow
air through until clean. To clean orifices use a
broom straw or toothpick. Never try and detach
dried material with sharp tool.

A.) Tighten air nozzle.

B.) Take off air nozzle and wipe off fluid tip, 

using rag moistened with thinner.

A.) Back up knurled nut, put a few drops of 

machine oil on packing, re-tighten nut.

B.) Take off fluid nozzle, clean rear of nozzle and 

seat in gun body. Replace nozzle and bring in 
tight to body.

C.) Tighten or change out swivel nut.

A.) Packing around needle valve 

is dried out.

B. Fluid nozzle loosely installed, 

or dirt between nozzle 
and body.

C.) Loose or defective swivel nut 

on siphon cup.

Fluid leakage from 
packing nut.

A.) Packing nut loose.

B.) Packing worn or dry.

A.) Tighten, but not so tight as to grip needle.

B.) Replace packing or lubricate.

Dripping from fluid tip.

A.) Dry packing.

B.) Sluggish needle.

C.) Tight packing nut.

D.) Worn fluid nozzle or needle.

A.) Lubricate.

B.) Lubricate.

C.) Adjust.

D.) For pressure feed, replace with new fluid nozzle 

and needle.

Thin, sandy coarse finish.

Thick, dimpled finish
resembling orange peel.

A.) Gun held too far from surface.

B.) Atomization pressure set 

too high.

Gun held too close to surface.

A.) Move gun closer to surface.

B.) Adjust atomization pressure.

Move gun further from surface.

Will not spray.

A.) No air pressure at gun.

B.) Fluid pressure too low with 

internal mix cap and 
pressure tank.

C.) Fluid control screw not 

open enough.

D.) Fluid too heavy for 

suction feed.

A.) Check air supply and air lines.

B.) Increase fluid pressure at tank.

C.) Open fluid control screw.

D.) Thin material or change to pressure feed.

Unable to get round spray.

Fan adjustment screw not 
seating properly.

Clean or replace.

Improper spray pattern.

A.) Gun improperly adjusted.

B.) Dirty air cap.

C.) Fluid tip obstructed.

D.) Sluggish needle.

A.) Readjust gun. Follow instructions carefully.

B.) Clean air cap.

C.) Clean.

D.) Lubricate.

Summary of Contents for 9004

Page 1: ... 9004 GRAVITY FEED SPRAY GUN CUP Operating Instructions Warning Information Parts Breakdown SPECIFICATIONS Fluid Orifice 1 4mm Air Inlet 1 4 NPT Rec Max Inlet Pressure 50 PSI CFM 3 1 at 50 PSI Nozzle Pressure 10 PSI ...

Page 2: ...h sound levels can cause permanent hearing loss Protect yourself from noise Noise levels vary with work surface Wear ear protectors When possible secure work with clamps or vise so both hands are free to operate tool Repetitive work motions awkward positions and exposure to vibration can be harmful to hands and arms Avoid inhaling dust or handling debris from work processes which can be harmful to...

Page 3: ...pray gun Therefore always mount the oil and water extractor at a point in the air supply system where the compressed air temperature is lowest Drain air lines properly Pitch all air lines back towards the compressor so that condensed moisture will flow back into the air receiver where it can be drained off Each low point in an air line acts as a water trap Such points should be fitted with an easi...

Page 4: ...zontal as shown here This provides a vertical fan shaped pattern which gives maximum even material coverage as the gun is moved back and forth parallel to the surface being finished Spray pattern may be infinitely adjusted from round to flat Set atomization pressure at no more than 50 PSI For optimum performance some materials may spray better at PSI ratings below 50 If unsure always test at PSI r...

Page 5: ...e of the gun 5 Oil gun daily Use a drop of lightweight machine oil on A fluid needle packing B air valve packing C trigger pivot point See Fig 1 for Location of Above Points 6 Caution Do not use lubricants which contain silicone Silicone may cause defects in the finish application AIR NOZZLE FLUID NOZZLE AIR VALVE ASSEMBLY 1 All nozzles and needles are made to exact standards They should be handle...

Page 6: ...nd body C Loose or defective swivel nut on siphon cup Fluid leakage from packing nut A Packing nut loose B Packing worn or dry A Tighten but not so tight as to grip needle B Replace packing or lubricate Dripping from fluid tip A Dry packing B Sluggish needle C Tight packing nut D Worn fluid nozzle or needle A Lubricate B Lubricate C Adjust D For pressure feed replace with new fluid nozzle and need...

Page 7: ...A 1722 1725A 1704 1713 1705 1706 1707 1708 1709 1710 1716 1726 1733 1715 1720 1714 1711 600CC 1729AL 1 9612N 0 1717 1718 1719 Optional Nozzle Kits Available 9004 1 4 1 4mm 9004 1 7 1 7mm 9004 2 0 2 0mm Nozzle Kits consist of 1 Air Cap 1 Fluid Needle 1 Fluid Nozzle 1700RK Includes all parts as asterisked on parts diagram ...

Page 8: ...Assembly 1714 Fan Adjustment 1715 Control Knob 1716 Paint Needle 1 4mm Standard 1717 Spring 1718 Lock for Fluid Control Knob 1719 Fluid Control Knob 1720 Screw 1722 Trigger 1724A Screw Nut 1725A Pin Clip 1726 Air Connection 1730A Spanner 1731 Socket Spanner 1732 Brush 1733 Air Adjusting Valve Assembly 9003PKG Material Filter 10 Pack 9612N 0 Hanger 600CC Replacement Aluminum Cup and Lid 1729AL 1 Ga...

Reviews:

Related manuals for 9004