background image

3

Rev. 04/10/03

GRAVITY FEED CUP HOOKUP

Air pressure for atomization is regulated at
extractor. Amount of fluid is adjusted by
fluid control screw on gun, viscosity of
paint, and air pressure.

Air Inlet

Air Hose

Oil and Water
Extractor

This spray gun is rugged in construction, and is built to yield exceptional value. The life of this product and the efficiency
of its operation depend upon a knowledge of its construction, use and maintenance.

INSTALLATION

Never mount oil and water extractor on or near the air compressor.

During compression, air temperature is greatly increased. As the air cools down to room temperature, moisture 
condenses in the air line, on its way to the spray gun. Therefore, always mount the oil and water extractor at a point in
the air supply system where the compressed air temperature is lowest. 

Drain air lines properly.

Pitch all air lines back towards the compressor so that condensed moisture will flow back into the air receiver where 
it can be drained off. Each low point in an air line acts as a water trap. Such points should be fitted with an easily 
accessible drain. See diagram above.

Drain

Length of Pipe (ft.)

Air Flow

CFM

50

100

150

200

10

20

30

40

50

70

1/2"

3/4"

3/4"

1"

1"

1"

3/4"

3/4"

3/4"

1"

1"

1"

3/4"

1"

1"

1"

1-1/4"

3/4"

3/4"

1"

1"

1"

1-1/4"

AIR SUPPLY

Fluid
Control
Screw

Gravity
Feed
Cup

Atomization
Pressure Gauge

Oil & Water

Extractor

Drain

Oil and Water Extractor should be at least 25 ft. from the compressor, farther if possible.

25 Feet or

More

Install drain at

each low point

Compressor Unit

Pitch pipe back toward air receiver

90045_op man_041003  4/18/03  1:59 PM  Page 3

Summary of Contents for 90045

Page 1: ...chemicals are lead from lead based paints crystalline silica from bricks and cement and other masonry products and arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are...

Page 2: ...cause permanent hearing loss Protect yourself from noise Noise levels vary with work surface Wear ear protection When possible secure work with clamps or vise so both hands are free to operate tool Repetitive work motions awkward positions and exposure to vibration can be harmful to hands and arms Avoid inhaling dust or handling debris from work processes which can be harmful to your health Operat...

Page 3: ...ways mount the oil and water extractor at a point in the air supply system where the compressed air temperature is lowest Drain air lines properly Pitch all air lines back towards the compressor so that condensed moisture will flow back into the air receiver where it can be drained off Each low point in an air line acts as a water trap Such points should be fitted with an easily accessible drain S...

Page 4: ...his provides a vertical fan shaped pattern which gives maximum even material coverage as the gun is moved back and forth parallel to the surface being finished Spray pattern may be infinitely adjusted from round to flat Set atomization pressure at no more than 50 PSI For optimum performance some materials may spray better at PSI ratings below 50 If unsure always test at PSI ratings before using on...

Page 5: ... daily Use a drop of lightweight machine oil on A fluid needle packing B air valve packing C trigger pivot point See Fig 1 for Location of Above Points 6 Caution Do not use lubricants which contain silicone Silicone may cause defects in the finish application AIR NOZZLE FLUID NOZZLE AIR VALVE ASSEMBLY 1 All nozzles and needles are made to exact standards They should be handled carefully 2 To clean...

Page 6: ...ective swivel nut on siphon cup Fluid leakage from packing nut A Packing nut loose B Packing worn or dry A Tighten but not so tight as to grip needle B Replace packing or lubricate Dripping from fluid tip A Dry packing B Sluggish needle C Tight packing nut D Worn fluid nozzle or needle A Lubricate B Lubricate C Adjust D For pressure feed replace with new fluid nozzle and needle Thin sandy coarse f...

Page 7: ...1706 RS1707 RS1708 RS1709 RS1710 RS1716 1 7 RS1726 RS1733 RS1715 RS1720 RS1714 RS1711 RS600CC RS1729AL 1 RS9612N 0 RS1717 RS1718 RS1719 Optional Nozzle Kits Available RS9004 1 4 1 4mm RS9004 1 7 1 7mm RS9004 2 0 2 0mm Nozzle Kits consist of 1 Air Cap 1 Fluid Needle 1 Fluid Nozzle RS1700RK Includes all parts as asterisked on parts diagram 90045_op man_041003 4 18 03 1 59 PM Page 7 ...

Page 8: ...ributed to that specific product This product carries a 90 day warranty During this warranty period Sunex Tools will repair or replace at our option any part or unit which proves to be defective in material or workmanship Other important warranty information This warranty does not cover damage to equipment or tools arising from alteration abuse misuse damage and does not cover any repairs or repla...