background image

SX264

 

4   

Rev. 6/16/20

mounted accessory must match the collet size fitted in the Die 

Grinder. Insert the shank of the mounted point as far as possible 

into the collet and tighten the nut using the supplied wrenches. 

Minimum shank gripping length must be 10mm.
Correct bonded abrasive mounted point grinding wheels, rotary 

files and carbide burrs are necessary to prevent injury from broken 

accessories. Do not use chipped or cracked bonded abrasive 

mounted point grinding wheels, rotary files and carbide burrs. 

Tighten the bonded abrasive mounted point grinding wheels, rotary 

files and carbide burrs on the collet to prevent spin off when the 

Die Grinder is turned off. 
After mounting a new point, start the Die Grinder under bench and 

run for a few seconds. If the Die Grinder starts to vibrate when first 

fitting a mounted point or during operation, immediately remove 

from service. 

If Die Grinder is dropped, replace bonded abrasive 

mounted point grinding wheel, rotary file or carbide burr.

 

When using the Die Grinder, be careful not to exert excessive 

force which could be hazardous and cause mounted spindle to 

bend or break. 

NOTE:  During operation, safety goggles should always be worn 

to guard against flying debris (users and bystanders).
WARNING: Never mount a grinding wheel, cut-off wheel, router 

cutter or drill bit on a Die Grinder. Never use an arbor, mandrel 

or any other adapter to convert the Die Grinder for any other 

application.

AIR SUPPLY

Tools operate on a wide range of air pressures. It is recommended 

that air pressure measures 90 psig at the tool with the trigger 

fully depressed and no load applied to the tool. Higher pressure 

(over 90 psig; 6.2 bar) raises performance beyond the rated 

capacity of the tool, which will shorten tool life and could cause 

injury. 
Always use clean, dry air. Dust, corrosive fumes and/or water in 

the air line will cause damage to the tool. Drain the water from 

air lines and compressor prior to running tool. Clean the air inlet 

filter screen  weekly. The recommended hookup procedure can 

be viewed in FIG. 1. 
The air inlet used for connecting air supply has standard 1/4" 

NPT. Line pressure should be increased to compensate for 

unusually long air hoses (over 25 feet). Minimum hose diameter 

should be 3/8" I.D. and fittings should have the same inside 

dimensions and be tightly secured.  

Ensure an accessible emergency shut off valve has been 

installed in the air supply line and make others aware of its 

location.

TROUBLESHOOTING

Other factors outside the tool may cause loss of power or erratic 

action. Reduced compressor output, excessive drain on the 

air line, moisture or restrictions in air pipes or the use of hose 

connections of improper size or poor conditions may reduce air 

supply. Grit or gum deposits in the tool may cut power and may 

be corrected by cleaning the air strainer and flushing out the 

tool with gum  solvent oil or an equal mixture of SAE #10 and 

kerosene. If outside conditions are in order, disconnect tool from 

hose and take tool to your nearest authorized service center.

LUBRICATION AND MAINTENANCE 

Lubricate the air motor daily with high quality air tool oil. If no air 

line oiler is used, run 1/2 oz. of oil through the tool. The oil can 

be squirted into the tool air inlet or into the hose at the nearest  

connection to the air supply, then run the tool. A rust inhibitive oil 

is acceptable for air tools.  

WARNING: After an air tool has been lubricated, oil will 

discharge through the exhaust port during the first few seconds 

of operation. The exhaust port must be covered with a towel 

before applying air pressure to prevent serious injury.

OPERATION

Always turn off the air supply, drain hose of air pressure 

and detach tool from air supply before installing, removing 

or adjusting any part or accessory on this tool, or before 

performing any maintenance on this tool.  

Bonded abrasive mounted point grinding wheels, rotary files 

and carbide burrs can be mounted providing their speed rating 

exceeds the speed of the Die Grinder. The shank size of the 

Operating Instructions • Warning Information • Parts Break down

Drain Daily 

Regulator 

Oiler 

Quick Coupler 

Leader 

Hose 

  

Nipple 

 Do Not Install

Quick Coupling

Here

  

  

 

Nipple 

  

Filter 

  

 

Air Supply 

  

 

Whip Hose 

fig. 1.

For a complete listing of Authorized Master Repair  

Centers, visit www. sunextools.com.

LIMITED WARRANTY

SUNEX INTERNATIONAL, INC. WARRANTS TO ITS 
CUSTOMERS THAT THE COMPANY’S SUNEX TOOLS® 
BRANDED PRODUCTS ARE FREE FROM DEFECTS IN 
WORKMANSHIP AND MATERIALS. 

 

Sunex International, Inc. will repair or replace its Sunex Tools® branded 
products which fail to give satisfactory service due to defective workmanship 
or materials, based upon the terms and conditions of the following described 
warranty plans attributed to that specific product. This product carries a 
ONE-YEAR warranty. During this warranty period, Sunex Tools® will repair or 
replace at our option any part or unit which proves to be defective in 
material or workmanship.

Other important warranty information...

This warranty does not cover damage to equipment or tools arising from 
alteration, abuse, misuse, damage and does not cover any repairs or 
replacement made by anyone other than Sunex Tools® or its authorized 
warranty service centers. The foregoing obligation is Sunex Tools® sole 
liability under this or any implied warranty and under no circumstances shall 
we be liable for any incidental or consequential damages.

Note:

 

Some states do not allow the exclusion or limitation of incidental or 

consequential damages, so the above limitation or exclusion may not apply 
to you. Return equipment or parts to Sunex Tools®, or an authorized 
warranty service center, transportation prepaid. Be certain to include your 
name and address, evidence of the purchase date, and description of the 
suspected defect.
If you have any questions about warranty service, please write to Sunex 
Tools®. This warranty gives you specific legal rights and you may also have 
other rights which vary from state to state. Repair kits and replacement 
parts are available for many of Sunex Tools® products regardless of whether 
or not the product is still covered by a warranty plan.

SHIPPING ADDRESS:

  

Sunex Tools  •  315 Hawkins Rd.  •  Travelers Rest, SC 29690

MAILING ADDRESS: 

Sunex Tools  •  P.O. Box 1233  •  Travelers Rest, SC 29690

SUNExpress™ Warranty

This airtool is under the SUNEXpress™ Warranty. Visit www.sunextools.
com/sunexpress for more details.

Summary of Contents for SX264

Page 1: ...cals are lead from lead based paints crystalline silica from bricks and cement and other masonry products arsenic and chromium from chemically treated lumber Your risk from these exposures varies depending on how often you do this type of work To reduce your exposure to these chemicals work in a well ventilated area and work with approved safety equipment such as those dust masks that are speciall...

Page 2: ...ms Discontinue use of tool if discomfort tingling feeling or pain occurs Seek medical advice before resuming use Slipping tripping and or falling while operating air tools can be a major cause of serious injury or death Be aware of excess hose left on the walking or work surface Keep body working stance balanced and firm Do not overreach when operating the tool Note direction of rotation BEFORE op...

Page 3: ... Assembly 1 16 RS26402A Air Motor Assembly 17 27 RS26403A Angle Head Assembly 26 30 35 RS26428 Connect Nut 28 RS26429 Clamp Nut 29 RS26437 1 4 Collet 37 RS26438 Collet Nut 38 RS26439 Wrench 39 RS26440 Wrench 40 RS26441 Air Inlet 41 SX264 1 4 MINI RIGHT ANGLE DIE GRINDER ...

Page 4: ...or daily with high quality air tool oil If no air line oiler is used run 1 2 oz of oil through the tool The oil can be squirted into the tool air inlet or into the hose at the nearest connection to the air supply then run the tool A rust inhibitive oil is acceptable for air tools WARNING After an air tool has been lubricated oil will discharge through the exhaust port during the first few seconds ...

Page 5: ... trabajo Para reducir su exposición a dichos químicos trabaje en una área bien ventilada y con equipo de seguridad aprobado tales como los máscaras anti polvo los que son específicamente diseñados para filtrar las partículas microscópicas ADVERTENCIA ADVERTENCIA LAS RPM DEL ACCESSORIO DEBEN EXCEDER LAS RPM DE LA HERRAMIENTA LEA EST MANUAL ANTES DE OPERAR ESTA HERRAMIENTA SIEMPRE LLEVE PUESTO PROTE...

Page 6: ...de la herramientasi experimente molestias estremecimiento o dolor Antes decontinuar usándola solicite el consejo médico Resbalarse tropezarse y o caerse durante la operación de herramientas neumáticas puede ser una causa mayor de lesión seria o la muerte Sea consciente de la manguera excedente dejada por la superficie para caminar o trabajar Mantenga balanceada y firme la postura corporal de traba...

Page 7: ... Un aceite anti corrosión es aceptable para las herramientas neumáticas El sobre rellenado ocasionará una reducción en la potencia de la herramienta ADVERTENCIA Después de que se haya lubricado una herramienta neumática el aceite se descargará por el puerto de escape durante los primeros segundos de la operación El puerto de escape deberá cubrirse con una toalla antes de aplicar una presión de air...

Page 8: ...ón antes mancionada queda bajo la responsabilidad exclusiva de Sunex Tools según se menciona o de cualquier garantía implícita y bajo ninguna circunstancia quedará bajo su responsabilidad cualquier garantía implícita ya bajo ninguna circunstancia quedará bajo su responsabilidad cualquier daño incidental o consecuencial Nota Algunos estados no permiten la exclusión o limitación de los daños inciden...

Page 9: ... travail pour réduire l exposition à ces expositions travaillez dans un endroit bien ventilé et travaillez avec l équipement de sécurité approuvé comme les masques à poussière qui sont conçus pour filtrer les particules microscopiques AVERTISSEMENT AVERTISSEMENT LE R MIN DE L ACCESSOIRE DOIT EXCÉDER CELUI DE L OUTIL SAUVEGARDER CES INSTRUCTIONS PORTEZ TOUJOURS DE PROTÈGE YEUX PORTEZ TOUJOURS DE PR...

Page 10: ...ramienta si experimente molestias estremecimiento o dolor Antes de continuar usándola solicite el consejo médico Une glissade un trébuchage et ou une chute lors de l utilisation d outils pneumatiques peut causer de sérieuses blessures ou la mort Prenez garde aux boyaux qui traînent par terre dans l aire de travail Votre posture doit être stable Évitez de travailler à bout de bras Vérifier le sens ...

Page 11: ...ctionner l outil L huile antirouille convient aux outils pneumatiques Un trop plein réduit la puissance de l outil AVERTISSEMENT Une fois l outil pneumatique lubrifié de l huile s écoulera de l orifice d échappement pendant les premières secondes de fonctionnement L orifice d échappement doit être recouvert d un chiffon avant de mettre en marche l outil pour prévenir les blessures graves MODE D EM...

Page 12: ...obligation qui précède constitue la seule responsabilité de Sunex Tools en vertu de cette garantie ou de toute garantie implicite et en aucun cas Sunex Tools ne pourra être responsable pour des dommages indirects ou consécutifs Remarque Certaines juridictions ne permettent pas l exclusion ou la limitation des dommages indirects ou consécutifs la limitation ou l exclusion ci dessus pourrait donc ne...

Reviews: