background image

SX959A/SX959A-2: 

Parts Breakdown & Operating Manual 

2  

Rev. 10/13/09

WARNING!

FAILURE TO OBSERVE THESE WARNINGS

 

COULD RESULT IN INJURY.

 

This  Instruction  Manual  Contains 

 

Important  Safety Information. 

 

Read  THIS  INSTRUCTION  MaNUaL 

 

CaRefULLy  aNd  UNdeRSTaNd  aLL 

 

INfORMaTION 

BefORe 

OpeRaTINg 

 

THIS TOOL.

 

•  Always  operate,  inspect  and  maintain  this 

 

  tool  in  accordance  with American  National 

 

  Standards Institute Safety Code of Portable 

 

  Air  Tools  (ANSI  B186.1)  and  any  other 

 

  applicable safety codes and regulations.

 

•  For  safety,  top  performance  and  maximum 

 

  durability  of  parts,  operate  this  tool  at  90 

 

  psig/6.2  bar  max  air  pressure  with  3/8" 

 

  diameter air supply hose.

 

•  Always wear impact-resistant eye and face 

 

  protection  when  operating  or  performing 

 

  maintenance  on  this  tool.  Always  wear 

 

  hearing protection when using this tool. 

 

•  High sound levels can cause permanent  

 

  hearing  loss.  Use  hearing  protection  as 

 

  recommended  by  your  employer  or 

 

  OSHA regulation.

 

•  Keep  the  tool  in  efficient  operating 

 

  condition.

 

•  Operators  and  maintenance  personnel 

 

  must be physically able to handle the bulk, 

 

  weight and power of this tool.

 

•  Air under pressure can cause severe injury. 

 

  Never  direct  air  at  yourself  or  others. 

 

  Always  turn  off  the  air  supply,  drain  hose 

 

  of  air  pressure  and  detach  tool  from  air 

 

  supply  before  installing,  removing  or 

 

  adjusting  any  accessory  on  this  tool,  or 

 

  before performing any maintenance on this 

 

  tool. Failure to do so could result in injury.  

 

  Whip hoses can cause serious injury.  

 

 

  Always check for damaged, frayed or loose 

 

  hoses  and  fittings,  and  replace 

 

  immediately.  Do  not  use  quick  detach 

 

  couplings  at  tool.  See  instructions  for 

 

 

  correct set-up.

  •  Air  powered  tools  can  vibrate  in  use. 

  Vibration, 

repetitive 

motions 

or 

  uncomfortable  positions  over  extended 

  periods  of  time  may  be  harmful  to  your 

  hands and arms. Discontinue use of tool if 

  discomfort, tingling feeling or pain occurs.  

   Seek medical advice before resuming use.

 

 

  •  Place  the  tool  on  the  work  before  starting 

 

  the  tool.  Do  not  point  or  indulge  in  any 

 

  horseplay with this tool.

 

•  Slipping,  tripping  and/or  falling  while 

 

  operating  air  tools  can  be  a  major  cause 

 

  of  serious  injury  or  death.  Be  aware  of 

 

  excess  hose  left  on  the  walking  or  

 

  work surface.

 

•  Keep  body  working  stance  balanced  and 

 

  firm.  Do  not  overreach  when  operating 

 

  the tool.

 

•  Anticipate and be alert for sudden changes 

 

  in  motion  during  start  up  and  operation  of 

 

  any power tool.

 

•  Do  not  carry  tool  by  the  hose.  Protect  the 

 

  hose from sharp objects and heat.

 

•  Tool  shaft  may  continue  to  rotate  briefly 

 

  after  throttle  is  released.  Avoid  direct 

 

  contact  with  accessories  during  and  after 

 

  use.  Gloves  will  reduce  the  risk  of  cuts  

 

  or burns.

 

•  Keep  away  from  rotating  end  of  tool.  

 

  Do  not  wear  jewelry  or  loose 

 

  clothing.  Secure  long  hair.  Scalping  can 

 

  occur  if  hair  is  not  kept  away  from  tool 

 

  and  accessories.  Choking  can  occur  if  

 

  neckwear  is  not  kept  away  from  tool  

 

  and accessories.

 

    •  Impact  wrenches  are  not  torque  con trol  

 

      devices.  Fas ten ers  with  spe cif ic  torque  

 

      re quire ments  must  be  checked  with  

 

      suit able  torque  measuring  de vic es  after  

 

      in stal la tion with an im pact wrench.

 

    •  Use  only  impact  wrench  sock ets  and  

 

      ac ces so ries  on  this  tool.  Do  not  use  hand  

 

      sock ets  and  ac ces so ries,  as  they  may  be  

 

      damaged or cause damage to the equipment  

 

      or operator.

 

    •  Do  not  lubricate  tools  with  flammable  or 

 

      volatile  liquids  such  as  kerosene,  diesel 

 

      or jet fuel.

 

•  Do not force tool beyond its rated capacity.

 

•  Do  not  remove  any  labels.  Replace  any 

 

  damaged labels.

 

•  Use  accessories  recommended  by 

 

  Sunex Tools®.

AVERTISSEMENT

AVERTISSEMENT

ADVERTENCIA

ADVERTENCIA

WARNING

WARNING

Summary of Contents for SX959A

Page 1: ...dust created by power sanding sawing grinding drilling and other construction activities contains chemicals known to cause cancer birth defects or other reproductive harm Some examples of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other masonry products and arsenic and chromium from chemically treated lumber Your risk from these exposures varies d...

Page 2: ...tion repetitive motions or uncomfortable positions over extended periods of time may be harmful to your hands and arms Discontinue use of tool if discomfort tingling feeling or pain occurs Seek medical advice before resuming use Place the tool on the work before starting the tool Do not point or indulge in any horseplay with this tool Slipping tripping and or falling while operating air tools can ...

Page 3: ...ront End Plate 1 20 RS95920 Rotor Blade 6 21 RS95921 Rotor 1 22 RS95922 Front Dowel Pin 1 23 RS95923 Cylinder 1 24 RS95924 Rear Dowel Pin 1 25 RS95925 Rear End Plate 1 26 RS227B25 Ball Bearing 1 27 RS95927 Gasket 1 28 RS95928 Back Cover 1 29 RS95929 Cap Screw 4 30 RS95930 Reverse Switch 1 31 RS95931 Detent Ball 1 32 RS95932 Detent Spring 1 33 RS95933 O Ring 2 34 RS95934 Reverse Knob 1 35 RS95935 R...

Page 4: ...hould have the same inside dimensions and be tightly secured Lubrication Lubricate the air motor daily with quality air tool oil If no air line oiler is used run 1 2 ounce of air tool oil through the tool by squirting oil into the tool s air inlet or into the nearest connection to the air inlet reconnecting air supply and then running tool Do not use more than 1 2 ounce of oil as overfilling will ...

Page 5: ...IO PESADO ENCAJE 1 2 SX959A 2 LLAVE DE IMPACTO RESISTENTE PARA SERVICIO PESADO CON YUNQUE EXTENDIDO ENCAJE 1 2 ESPECIFICACIONES El polvo creado por la lijación eléctrica la aserradura la trituración la perforación y otras actividades de construcción contiene químicos conocidos como causantes de cáncer defectos de nacimiento u otros daños a reproducción Algunos ejemplos de dichos químicos son El pl...

Page 6: ...o posiciones incómodas durante períodos extendidos de tiempo pueden ser dañinos para sus manos y brazos Suspenda el uso de la herramienta si experimente molestias estremecimiento o dolor Antes de continuar usándola solicite el consejo médico Coloque la herramienta sobre el trabajo antes de arrancar la herramienta No la apunte en dirección de una persona y no juede con esta herramienta Resbalarse t...

Page 7: ...montaje gire el regulador hacia la posición completamente abierta La llave de impacto tiene un índice de tamaño para tuercas de 12 7 mm 1 2 USS Debe degradar el índice para tuercas con resorte en U tuercas de montaje largos tornillos sin cabeza tuercas de doble profundidad para las condiciones de oxidación importante y para las abrazaderas con resorte ya que amortiguan en gran parte laz potencia d...

Page 8: ...LONGÉ SPÉCIFICATIONS Certaines poussières produites par le sablage le sciage le meulage le perçage et autres activités de construction contiennent des produits chimiques qui peuvent causer le cancer des anomalies congénitales ou autres problèmes de reproduction Voici quelques exemples de produits chimiques Plomb provenant des peintures Silicium cristallin provenant des briques du ciment et d autre...

Page 9: ...rolongées peuvent durs sur les mains et les ras Arrêtez d utiliser l outil si vous vous sentez mal à l aise si vous sentez des fourmillements ou des douleurs Consultez un médecin avant de d utiliser l outil de nouveau Placez l outil sur le travail avant de le faire démarrer Ne pointez jamais l outil sur quelqu un Évitez toute chamaillerie quand vous avez l outil en main Si vous glissez trébuchez e...

Page 10: ...on de pleine ouverture Cette clé à chocs est calibrée pour les boulons à filets USS de 1 2 po L outil doit être ajusté dans le cas de boulons de ressort en U de boulons d ancrage de longues vis d assemblage d écrous double longueur de pièces de fixation à ressort ou d écrous très rouillés car ceux ci absorbent la plus grande partie de la force d impact Dans la mesure du possible coincer ou caler l...