background image

12

Model

Cell Size

(mm)

Model Size

(mm)

Voc

(Vdc)

Isc

(A)

Vmp

(Vdc)

Imp

(A)

Pmax

(W)

FLEX60-XXXW

FLEX55-XXXW

FLEX54-XXXW
FLEX50-XXXW

FLEX48-XXXW

FLEX45-XXXW

FLEX44-XXXW

FLEX42-XXXW

FLEX40-XXXW

FLEX36-XXXW

FLEX35-XXXW
FLEX33-XXXW
FLEX32-XXXW

156 x 156

156 x 156
156 x 156
156 x 156

156 x 156

156 x 156
156 x 156
156 x 156
156 x 156

156 x 156

156 x 156
156 x 156
156 x 156

1660 x 990

1860 x 828

1520 x 990

1702 x 828

1344 x 990

1976 x 670
1544 x 828

1818 x 670

1186 x 990

1386 x 828

1028 x 990

1228 x 828

1860 x 512

1344 x 670

1502 x 670

2018 x 512

1660 x 670

38.00

33.83

33.4
30.8

29.6
29.6

27.7

27.1

25.8

25

22.2

21.5

20.3

20

19.7
19.5
19.3

24.8
24.6
24.2

24

30.6
30.4

30

29.8

37.60

36.93
36.63

36.4

35.95

35.74

35.42

35.11

7.70

7.40
7.40

7.54

7.4
7.4
7.4
7.4
7.4

7.54

7.4

7.4
7.4

7.54

7.53

7.43
7.42

7.53

7.43
7.42
7.38

7.53

7.43
7.42
7.38

7.60

7.54

7.53

7.43
7.42
7.38

7.28

7.19

30.30

26.2

25.7

24.6

23
23

21.4

21

20

19.8

17.1

16.7
15.7

16

15.3

14.96

14.5

19.4

19.12

18.55

18

24.1

23.9
23.4
22.9

29.86
29.26

28.33
28.68

28.18

27.37

27.5

27.63

6.60

6.3
6.3
6.5

6.4
6.4

6.3
6.3
6.3

6.55

6.3

6.3
6.3

6.55
6.53
6.35

6.21

6.43

6.28

6.2

6.11

6.43

6.28

6.2

6.11

6.53

6.49

6.53
6.28
6.22

6.21

6.0

5.8

200

165
162

160

145
145

135
132
126

130

108

105

99

105

100

95

90

126

120

115

110

155

150
145

140

195

190

185

180

175

170
165

160

V2.0 Model list

Frameless module

Model series FLEXYY-XXXW Z”, where “YY” suffix indicates the number of solar cells, “XXX” suffix 

the power classes “Z” suffix indicates the size of cells (127mm x 127mm), blank is default size 

(156mm x 156mm).

Cell technology is CIGS with bypass diode for each cell.

Summary of Contents for FLEX60

Page 1: ...Installation Instructions for the FLEX60 Photovoltaic Modules...

Page 2: ...These instructions are intended as a guideline for professional solar system integrators only The Installation Instructions for the FLEX60 Photovoltaic Modules 2 FLEX60 modules are not intended for i...

Page 3: ...module s encapsulation system has been compromised Have qualified personnel ensure there is no leakage current and the system is in safe working order before walking on or working on the modules Dang...

Page 4: ...act as a sail in even low wind conditions knocking or pulling an installer off a roof In addition panels can become missiles if unsecured and blown away by the wind A flying module can injure roofers...

Page 5: ...que Identifier A record of the modules serial numbers should be made before installation and this should be included in the system documentation to be saved The module s serial number is located on th...

Page 6: ...m installing the modules Roof Membrane Prep The roof surface must be thoroughly cleaned prior to installation and primed if required to meet load requirements The surface needs to be free from dust an...

Page 7: ...e tape In most circumstances soap and water is sufficient If required IPA can be used to clean the module s top surface Follow the roofing manufacturer s instructions for cleaning the roofing surface...

Page 8: ...stay hidden under the wire tray top cover once it is installed Use only solar ties or other polymeric wire ties with application appropriate UV and environmental resistance Do not use commercially ava...

Page 9: ...ired length prior to installation Finally install the end caps to the top covers at both exposed ends of the row as shown in Figure 11 Use an outdoor rated PVC cement to join the end cap to the top co...

Page 10: ...conditions and installation practices it is recommended to fully inspect the system and all connections every 6 months Read these installation instructions thoroughly before inspecting or servicing a...

Page 11: ...ancial losses of any kind business interruptions or lost earnings whether they be direct or incidental as a result of the use of the information contained in these instructions and whether or not they...

Page 12: ...35 42 35 11 7 70 7 40 7 40 7 54 7 4 7 4 7 4 7 4 7 4 7 54 7 4 7 4 7 4 7 54 7 53 7 43 7 42 7 53 7 43 7 42 7 38 7 53 7 43 7 42 7 38 7 60 7 54 7 53 7 43 7 42 7 38 7 28 7 19 30 30 26 2 25 7 24 6 23 23 21...

Page 13: ...x 828 712 x 990 1228 x 512 1818 x 354 754 x 828 554 x 990 712 x 670 596 x 828 1186 x 354 670 x 554 870 x 354 512 x 596 712 x 354 554 x 354 396 x 354 754 x 512 1028 x 354 1070 x 512 1344 x 354 912 x 5...

Page 14: ...7 37 27 5 27 63 6 60 6 53 6 49 6 53 6 28 6 22 6 21 6 0 5 8 200 195 190 185 180 175 170 165 160 V2 0 Model list Frame module Model series FLEXYY XXXW M20 A where YY suffix indicates the number of solar...

Page 15: ...A 12 A 1000V MC4 Liability Limitation Sunflare accepts no liability for damages of any kind as a result of the use of the information contained in this instruction Sunflare is not in control of instal...