Appendix V: System Menu Setting Procedures

Note

When you quit and save the menu setting, please set the menu

to POO, then press the SET to RUNX, then it is OK, You also can press

‘STOP’ button to quit and save menu setting too. And then resume

power to test.

Appendix VI: Setting Menu Explanations

LP01: Working mode(0 is Continuous testing mode

1 is Normal working mode)

LP02

Auto delay time setting.(0-60, 0 is NO auto close, for example

3 means

barrier gate will auto close in 3 sec after opened)

LP03

RS485 address(0-255)(optional)

RS485 communication equipment address (barrier gate or control board)

LP04

Default

DP01: Max open speed range(1-16)

The highest speed when opening

DP02: Opening brake pulse duration(0-255)

The speed need to be controlled to achieve when opening to close position,

the bigger the value, the slower the speed controlled, vice verse. Default

value is 5.

DP03: The stating brake angle of opening (37-90)

The starting angle of braking when opening

DP04: Max braking strength when opening(0-10)

The strength of braking when opening

DP05: Max close speed range(1-16)

The highest speed when closing

DP06: Closing brake pulse duration(0-255)

The speed need to be controlled to achieve when closing to close position,

the bigger the value, the slower the speed controlled, vice verse. Default

value is 5.

DP07: Max braking strength when closing(0-10)

The strength of braking when closing

DP08: Default

DP10: Opening angle (0-100)

Horizontal degree is 0, when power on, barrier gate will auto close to find

0position, open to position degree is about 90 degrees. Sometimes the

degrees will more than or less than because of mechanical parts

matching or precision issues.

DP11

The lowest running speed(1-16)

The end speed of barrier gate opening or closing to position. The longer

the arm, the bigger the value. Normal value is 1, if too big, barrier arm

will be shake. If over loaded, can increase the value by one

DP12: First speed/Max auto revers speed.(1-16)

Closing Speed of auto finding 0 point (First power on or resume power),

also the maximum auto-revers speed. Normal value 5 or 6.

Normally, just need to adjust DP04/05/07/08 when arm is shaking in closing or

opening, others default.

Non-User Menu

NP02: Reset control board

Enter this menu, display P-H, long press button INC unitle display P-F,

then all parameters are default.

NP03: Arm detection

R UN0

Power on

0

P 0

Press SET

P 0

Press INC

1

0 0

Press SET

1

0 0

Press INC

2

0

Press SET

1

P

0

Press DEC

0

P

Press SET

R UN0

L

L

Note:

SET is Function Key
INC is Increase
DEC is Decrease
Menu in&out is P00

Menu has 3 series :

L is Logical menu
D is Drive menu

N is Non-users menu

This is Cyclic Menu

When system in work, Digitron displays RUNX

Press ‘STOP’ to save
and quit menu

Or

Summary of Contents for S10

Page 1: ...Operating Instructions DC Servo Barrier Gate S10 SFMCU MicroDrive V1 0 ...

Page 2: ... Introduction SUNFRE S10 DC Brushless Servo motorized barrier gate the newly designed maintenance free with exclusive SFMCU MicroDrive unit offers 100 more torque 100 duty are the fastest toll barriers available with an opening time as fast as 0 6 seconds Opening speed is adjustable from 0 6s 0 9s to 6s or more This barrier redefines performance in non stop toll applications It is the ideal soluti...

Page 3: ...cess Reader or Push button or remote controller can be used to trigger the barrier gate to open via a simply dry contact signal After delay timer elapsed barrier gate will close automatically by itself in a certain time optional function 3 8 USER FRIENDLY Motorized arms provide comfortable passage while maintaining a high level and high density of car flow management such as in toll gate 3 10 AUTO...

Page 4: ...nscrew the fastening wing nuts in the bottom of the spring by manual then take off the spring The steps for installation and dis assembly the spring are the opposite 6 2 3 Spring force adjustment When power off adjust the springs balance to make sure the arm will stay in the angle 45 60 degrees towards the horizontal and not going down or going up which mean the spring force is well balanced 7 Cont...

Page 5: ...signal disappeared boom will auto falling to closed 7 1 9 RS485 interface This interface is used for communication between computer and SFMCU control unit We provide SDK for customers to develop software to receive barrier gate status and control barrier gate operations 7 1 10 Battery interface This interface is used for battery the battery can be used to keep barrier gate working normal when powe...

Page 6: ...below items and situations are not included in the range of free service 10 4 1 The user does not follow the instruction and cause any damage of the product 10 4 2 The power supply is not stable over the range of permitted voltage or not accordant to safety electric using standard 10 4 3 The user installs or uses the product in wrong methods cause damage to the appearance of product 10 4 4 Natural...

Page 7: ...ttom port is state 0 Empty is state X The code as below is 10XX0X1X Warning please take out the battery before coding Appendix III Wiring Diagram for R G Light Interface Appendix IV Wiring Diagram for up and down limit output No need Power Boom Length Meter M Spring Diameter Φ mm Suggested max speed Straight Boom Link Hole Selection 2 L 2 5 empty 3 5 0 6 4 L 3 empty 4 5 0 9 4 5 L 4 3 5 4 5 1 2 6 L...

Page 8: ...the speed controlled vice verse Default value is 5 DP07 Max braking strength when closing 0 10 The strength of braking when closing DP08 Default DP10 Opening angle 0 100 Horizontal degree is 0 when power on barrier gate will auto close to find 0position open to position degree is about 90 degrees Sometimes the degrees will more than or less than because of mechanical parts matching or precision is...

Page 9: ...CHAS CHACK SENSOR Sensor check E PL ERROR PULSE Motor Default Phase E CS Gate operation overtime RUNX X is the system operation Mode and the Setting Value of LP02 System Normally Operating dPXX Menu Driven Display NPXX no User Menu Display P H Dates resuming to be Default Value P F Dates resuming Default Value NOPR NO POWER Opening when no power TEST Gate self testing INXX IN NUM xxthe entering ve...

Reviews: