Start delay after
communication recovery *
After the Smart Energy Meter recovers normal
communication, the Logger1000 will deliver start
instruction to the inverter.
Parameter range: 0~120s
Feed-in stop *
Enable: when feed-in power is detected,
theLogger1000 will deliver start instruction to the
inverter.
Disable: when feed-in power is detected,
theLogger1000 will not deliver start instruction to the
inverter.
Note: Never turn on the Enable switch arbitrarily!
Generally, keep it in Disable state.
Control cycle
Time interval of delivering dispatching instructions
Parameter range: 5~60s
Q-Method
kW: set active power value
%: set active power percentage
Note: *Only when the control method is set to "Closed-loop control", the parameter "-
Select energy meter" is settable.
Step 4
Add local power control manner
Fill in "Start time" and "Percentage" (fixed value of active power), and click "Save".
-- -- E
En
nd
d
S
Su
ub
bsse
eq
qu
ue
en
ntt O
Op
pe
erra
attiio
on
n
Delete local power control manner: select a local control manner that needs to be
deleted, and click "Clear data".
10.3.1.4 AI Control
When using the analog signal at the AI port of the Logger1000 as the dispatching input,
set the active control mode to "Analog input".
Step 1
Click "Power control" -> "Active power" to enter the active power interface.
Step 2
Set the active control mode to "Analog input".
Step 3
Set AI control parameters. For specific parameter description, refer to the following
table.