13 FAQ
Q1. How many types of communication ports does the Logger4000 support, what are
the corresponding ports, and how to set the port parameters?
T
Tyyp
pe
e
P
Po
orrtt
P
Pa
arra
am
me
ette
err sse
ettttiin
ng
g
Ethernet
FE1~FE4
Default IP: 12.12.12.12; subnet mask: 255.255.255.0
Gateway: 12.12.12.1
DNS1: 1.2.4.8
DNS2: 8.8.8.8
RS485
A1B1~A7B7
Default Baud rate: 9600
Check bit: Null
Data bit: 8
Stop bit: 1
PLC
L1,L2,L3
Default Baud rate: 115200
Check bit: Null
Data bit: 8
Stop bit: 1
Q2. What are the forwarding protocols supported by the Logger4000?
P
Prro
otto
oc
co
oll
D
De
essc
crriip
pttiio
on
n
ModbusRTU/ModbusTCP
The Logger4000 sends the collected data of devices (-
such as inverter, combiner box, Meteo Station) to the
background. The background allocates forwarding
addresses to theses devices, thereby accessing and
obtaining the data of the devices.
IEC104
1. Add or search devices on the Web interface (such
as inverter, combiner box, Meteo Station).
2. Export the IEC104 point table by clicking "Settings"
-> "IEC104 service settings". The point table shows
measuring point information of devices.