103
P
Pa
arra
am
me
ette
err
S
SH
H4
4..0
0R
RS
S
S
SH
H5
5..0
0R
RS
S
S
SH
H6
6..0
0R
RS
S
Max. AC output power
4000 VA
4999 VA for
"AU", 5000 VA
for others
6000 VA
Max. AC output current
18.2 A
21.7 A for "AU",
22.8 A for others
27.3 A
Nominal AC voltage
220 V / 230 V / 240 V
AC voltage range
154 V – 276 V
Nominal grid frequency
50 Hz / 60 Hz
Grid frequency range
45 Hz – 55 Hz / 55 Hz – 65 Hz
Harmonic (THD)
< 3 % (of rated power)
Power factor at nominal
power / Ajustable power
factor
> 0.99 at default value at nominal power (adj. 0.8 overex-
cited / leading–0.8 underexcited / lagging)
Feed-in phases / connec-
tion phases
1 / 1
E
Effffiic
ciie
en
nc
cyy
Max. efficiency
97.6 %
97.7 %
97.7 %
European efficiency
97.2 %
97.3 %
97.3 %
P
Prro
otte
ec
cttiio
on
n
Grid monitoring
Yes
DC reverse polarity
protection
Yes
AC short circuit protection
Yes
Leakage current
protection
Yes
Surge protection
DC Type II /AC Type II
DC switch (solar)
Yes
DC fuse (battery)
Yes
Arc fault circuit interrupter
(AFCI)
Yes
PID recovery
Yes
Battery input reverse po-
larity protection
Yes
B
Ba
atttte
erryy D
Da
atta
a
Battery type
Li-ion battery
Battery voltage
80 V – 460 V
Max. charge / discharge
current
30 A / 30 A
User Manual