Quick User Manual
2 Electrical Connection
11
2.6.2 Connecting the CAN Cable
The CAN cable enables
communication between the inverter and the Li-ion battery
from LG, GCL, Pylon (US2000B), BlueSun, BYD or Sungrow.
Take out the CAN cable from the packaging. Lead the cable through the cable gland
and tighten the wires to the corresponding terminals.
For GCL/BlueSun/BYD battery, please cut through the green (pin 6) and
white-green (pin 3) wires from the CANH and CANL terminals to set up
successful communication.
2.6.3 Connecting the RS485 Cable
The RS485 cable enables
communication between the inverter and the Pylon Li-ion
battery US2000A.
Cross-section: 2*0.5 mm², cable diameter: 3 mm–5.3 mm