5 Operation
Quick User Manual
30
State
Description
Upgrade
The DSP or LCD software is in its upgrading process.
Error
If an error occurs, the inverter will automatically stop operation,
trigger the AC relay and show “Error” on the LCD with the
indicator lit red.
Upd-fail
The master DSP program online upgrade failure.
If the inverter is in standby mode for more than 10 minutes, please check:
Whether the insolation is sufficient and the PV connection is correct.
Whether the battery level is sufficient and the cable connection is correct.
If no anomaly is found, disconnect the DC switch and main switch to
restart.
If it still does not work, contact SUNGROW.
5.2
Viewing the Error Codes
Viewing the Active Error
For the
icon or the “Error” state on the main
screen,
press
to view the active errors. Refer
to “
6 Troubleshooting
” for the fault definition.
Refer to the following table for the fault type explanations.
Fault Type
Explanation
GRID
Grid faults (AC side)
PV
PV faults (DC side)
SYS
System faults (inverter)
PER Permanent
faults
WARN Warnings
BDCF Faults
of
battery
charge/discharge circuit
BDCPF
Permanent faults of battery charge/discharge circuit
BATW Battery
warnings
BATP Battery
protection
BATF1
Battery faults
BATF2