Quick User Manual
7 Appendices
45
Power factor
> 0.99 at default value at nominal power
(adj. 0.8 overexcited/leading–0.8
underexcited/lagging)
Protection
Anti-islanding protection
Yes
AC short circuit protection
Yes
Leakage current protection
Yes
DC switch (solar)
Yes
DC fuse (solar)
No
DC fuse (battery)
Yes
Over-voltage category
III [Main], II [PV] [Battery]
System Data
Max. efficiency
97.7 %
97.7 %
Max. European efficiency
97.0 %
97.2 %
Max. charge / discharge efficiency
94.0 %
94.0 %
Isolation method (solar)
Transformerless
Isolation method (battery)
HF
Ingress protection (IP) rating
IP65
Power loss in night mode
< 1 W
Operating ambient temperature range
-25
℃
to 60
℃
(
>
45
℃
derating)
Allowable relative humidity range
0–100 %
Cooling method
Natural convection
Max. operating altitude
2000 m
Display Graphic
LCD
Communication
2 x RS485, Ethernet, Wi-Fi (optional), CAN
Analogue input
PT1000
Power management
1 x Digital output
Earth fault alarm
1 x Digital output, email, buzzer inside
PV connection type
MC4
AC connection type
Clamping yoke connector
Certificates and approvals (planned)
VDE-AR-N-4105, DIN VDE0126-1-1, G83/2,
CEI 0-21, IEC 62109-1, IEC62109-2, EN
62477-1, EN 61000-6-1/-3
Mechanical Data
Dimensions (W x H x D)
457 mm x 515 mm x 170 mm
Mounting method
Wall-mounting bracket
Weight 22
kg
Summary of Contents for SH3K6
Page 2: ......
Page 4: ...II System Overview ...
Page 5: ...III ...
Page 6: ...IV ...
Page 7: ...V ...
Page 8: ...VI ...
Page 28: ...3 Commissioning Quick User Manual 18 Fig 3 2 Initial Settings ...